Infectious Disease and Public Health Laboratory Developed Tests
Short answer: Infectious disease and public health LDTs let laboratories test for emerging or uncommon pathogens, resistance markers and outbreaks when no FDA-cleared test exists. CLIA requires the same 42 CFR 493.1253(b)(2) validation, with extra attention to inclusivity, cross-reactivity, limit of detection in each specimen matrix and strategies for scarce positive samples.
Last reviewed: November 18, 2026. Primary sources: 42 CFR 493.1253, CRS IF11389, APHL verification and validation toolkit and FDA emergency use authorization.

The role of LDTs in infectious disease and public health
CRS notes LDTs are used for “identifying evolving diseases (e.g., new strains of infectious disease)” and that COVID-19 showed “the pivotal role LDTs play in facilitating rapid access to tests” (CRS). The NIH SEED guide lists flu tests, emerging pathogen tests and COVID-19 assays as LDT examples (NIH SEED). APHL has described public health laboratories bringing up testing for emerging threats such as Oropouche virus (APHL).
Common infectious disease LDTs
| Test type | Examples | Key validation issue |
|---|---|---|
| Single-target PCR | Emerging or uncommon pathogens | Inclusivity across strains; LoD in matrix |
| Multiplex syndromic panels | Respiratory, GI, urinary or STI panels | Cross-reactivity, target competition |
| Resistance markers | Bacterial resistance genes or mutations | Correlation with phenotypic results |
| Sequencing | Viral identification, whole-genome sequencing for outbreaks, metagenomics | Reference databases, contamination |
| Serology | Antibody tests for new agents | Cross-reactivity with related viruses |
| Modified FDA-cleared assays | Cleared assay on an unapproved specimen type | Matrix equivalence |
The CMS/CDC 2026 CLIA RFI named NGS for bacterial resistance mutations and viral identification as applications with unique performance characteristics (91 FR 43586).
Validation priorities
- Inclusivity: show the assay detects the strains and variants it claims; combine in silico analysis with wet testing.
- Cross-reactivity and specificity: test near-neighbor organisms and normal flora (specificity guide).
- LoD in each matrix: swab media, urine, plasma and others differ (LoD guide).
- Scarce positives: plan for contrived samples, reference panels and accruing clinical positives, and document the rationale (APHL toolkit, APHL).
- Multiplex effects: target competition and co-infection; ADLM lists cross-reactivity, target competition and analytical interference among analytes (ADLM).
- Molecular QC: extraction and inhibition controls under 493.1256(d)(3) (molecular LDT validation).
Emergencies and emergency use authorization
FDA can issue emergency use authorizations under section 564 of the FD&C Act after a qualifying declaration (FDA). CRS notes that during COVID-19 many LDT developers did not realize their tests needed an EUA, and FDA later reported that some LDTs used under its notification policy were poorly validated (CRS). After the 2025 ruling that LDTs are not devices, how emergency policies will apply to LDTs is among the open questions CRS raises. Plan validation so it holds up regardless: CLIA 493.1253 applies in an emergency too.
Building, validating or fixing an LDT? We help CLIA labs plan and document LDT development and validation and prepare for CLIA, CAP and New York State review.
Public health laboratory considerations
- Coordinate reference materials and specimen sharing through public health networks.
- Document rapid bring-up decisions and later full validation.
- Track New York requirements for tests on NY specimens (NYS CLEP).
- Keep alternative assessment twice a year when no PT exists (alternative assessment).
Related microbiology guides
How Sound Lab Consultants helps
- Design inclusivity, cross-reactivity and LoD studies for each target and matrix.
- Plan scarce-positive strategies and document the rationale.
- Build rapid bring-up and full validation packages for new pathogens.
- Prepare CLIA, CAP and NYS files for infectious disease LDTs.
Talk through your test with an LDT regulatory consultant. Bring your intended use, platform and target launch date.
Frequently asked questions
What is an infectious disease LDT?
A test for a pathogen, resistance marker or immune response that a single CLIA-certified laboratory designs, makes and runs itself, often because no FDA-cleared test exists for the target or specimen.
How do you validate a PCR LDT for an emerging pathogen?
Establish accuracy, precision, limit of detection in each matrix, inclusivity across strains, cross-reactivity with related organisms, reportable range and stability under 42 CFR 493.1253(b)(2), using contrived samples where real positives are scarce.
Do public health labs use LDTs?
Yes. Public health laboratories use LDTs for emerging threats and surveillance, as APHL has described for viruses such as Oropouche.
Do infectious disease LDTs need an EUA during an emergency?
During COVID-19, FDA required emergency use authorization for many LDTs. After the 2025 court ruling that LDTs are not devices, how emergency policies apply to LDTs is an open question. CLIA validation applies either way.
What QC does a molecular infectious disease LDT need?
CLIA requires controls appropriate to the method, including extraction and amplification controls for molecular tests under 42 CFR 493.1256(d)(3), plus PT or alternative assessment.
Sources
- 42 CFR 493.1253
- 42 CFR 493.1256
- 42 CFR 493.1236
- CRS In Focus IF11389
- NIH SEED regulatory knowledge guide (PDF)
- APHL verification and validation toolkit
- APHL: Oropouche and laboratory testing
- FDA: Emergency use authorization
- 91 FR 43586 CLIA RFI
- ADLM response to CMS CLIA RFI (PDF)
Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the College of American Pathologists, the New York State Department of Health or any accrediting organization or Medicare contractor. This page is general regulatory information, not legal advice. Confirm current requirements with the agency or accreditor that oversees your laboratory. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.