Infectious Disease and Public Health Laboratory Developed Tests

Short answer: Infectious disease and public health LDTs let laboratories test for emerging or uncommon pathogens, resistance markers and outbreaks when no FDA-cleared test exists. CLIA requires the same 42 CFR 493.1253(b)(2) validation, with extra attention to inclusivity, cross-reactivity, limit of detection in each specimen matrix and strategies for scarce positive samples.

Last reviewed: November 18, 2026. Primary sources: 42 CFR 493.1253, CRS IF11389, APHL verification and validation toolkit and FDA emergency use authorization.

Book a free consultation

Gloved hands handling swab transport tubes and PCR strip tubes inside a biosafety cabinet with a real-time PCR instrument in an infectious disease laboratory
LDTs fill gaps when new pathogens appear before commercial kits.

The role of LDTs in infectious disease and public health

CRS notes LDTs are used for “identifying evolving diseases (e.g., new strains of infectious disease)” and that COVID-19 showed “the pivotal role LDTs play in facilitating rapid access to tests” (CRS). The NIH SEED guide lists flu tests, emerging pathogen tests and COVID-19 assays as LDT examples (NIH SEED). APHL has described public health laboratories bringing up testing for emerging threats such as Oropouche virus (APHL).

Common infectious disease LDTs

Infectious disease LDT types
Test typeExamplesKey validation issue
Single-target PCREmerging or uncommon pathogensInclusivity across strains; LoD in matrix
Multiplex syndromic panelsRespiratory, GI, urinary or STI panelsCross-reactivity, target competition
Resistance markersBacterial resistance genes or mutationsCorrelation with phenotypic results
SequencingViral identification, whole-genome sequencing for outbreaks, metagenomicsReference databases, contamination
SerologyAntibody tests for new agentsCross-reactivity with related viruses
Modified FDA-cleared assaysCleared assay on an unapproved specimen typeMatrix equivalence

The CMS/CDC 2026 CLIA RFI named NGS for bacterial resistance mutations and viral identification as applications with unique performance characteristics (91 FR 43586).

Validation priorities

  • Inclusivity: show the assay detects the strains and variants it claims; combine in silico analysis with wet testing.
  • Cross-reactivity and specificity: test near-neighbor organisms and normal flora (specificity guide).
  • LoD in each matrix: swab media, urine, plasma and others differ (LoD guide).
  • Scarce positives: plan for contrived samples, reference panels and accruing clinical positives, and document the rationale (APHL toolkit, APHL).
  • Multiplex effects: target competition and co-infection; ADLM lists cross-reactivity, target competition and analytical interference among analytes (ADLM).
  • Molecular QC: extraction and inhibition controls under 493.1256(d)(3) (molecular LDT validation).

Emergencies and emergency use authorization

FDA can issue emergency use authorizations under section 564 of the FD&C Act after a qualifying declaration (FDA). CRS notes that during COVID-19 many LDT developers did not realize their tests needed an EUA, and FDA later reported that some LDTs used under its notification policy were poorly validated (CRS). After the 2025 ruling that LDTs are not devices, how emergency policies will apply to LDTs is among the open questions CRS raises. Plan validation so it holds up regardless: CLIA 493.1253 applies in an emergency too.

Building, validating or fixing an LDT? We help CLIA labs plan and document LDT development and validation and prepare for CLIA, CAP and New York State review.

Book a free consultation

Public health laboratory considerations

  • Coordinate reference materials and specimen sharing through public health networks.
  • Document rapid bring-up decisions and later full validation.
  • Track New York requirements for tests on NY specimens (NYS CLEP).
  • Keep alternative assessment twice a year when no PT exists (alternative assessment).

Related microbiology guides

How Sound Lab Consultants helps

  • Design inclusivity, cross-reactivity and LoD studies for each target and matrix.
  • Plan scarce-positive strategies and document the rationale.
  • Build rapid bring-up and full validation packages for new pathogens.
  • Prepare CLIA, CAP and NYS files for infectious disease LDTs.

Talk through your test with an LDT regulatory consultant. Bring your intended use, platform and target launch date.

Book a free consultation

Frequently asked questions

What is an infectious disease LDT?

A test for a pathogen, resistance marker or immune response that a single CLIA-certified laboratory designs, makes and runs itself, often because no FDA-cleared test exists for the target or specimen.

How do you validate a PCR LDT for an emerging pathogen?

Establish accuracy, precision, limit of detection in each matrix, inclusivity across strains, cross-reactivity with related organisms, reportable range and stability under 42 CFR 493.1253(b)(2), using contrived samples where real positives are scarce.

Do public health labs use LDTs?

Yes. Public health laboratories use LDTs for emerging threats and surveillance, as APHL has described for viruses such as Oropouche.

Do infectious disease LDTs need an EUA during an emergency?

During COVID-19, FDA required emergency use authorization for many LDTs. After the 2025 court ruling that LDTs are not devices, how emergency policies apply to LDTs is an open question. CLIA validation applies either way.

What QC does a molecular infectious disease LDT need?

CLIA requires controls appropriate to the method, including extraction and amplification controls for molecular tests under 42 CFR 493.1256(d)(3), plus PT or alternative assessment.

Sources

Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the College of American Pathologists, the New York State Department of Health or any accrediting organization or Medicare contractor. This page is general regulatory information, not legal advice. Confirm current requirements with the agency or accreditor that oversees your laboratory. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.