New Mexico CLIA Laboratory Requirements: Health Care Authority, NMAC Laboratory Rules, and CMS-116

Your custom embed code

New Mexico CLIA Laboratory Requirements: Health Care Authority, NMAC Laboratory Rules, and CMS-116

Short answer: New Mexico clinical laboratories, including physician office laboratories, are certified under federal CLIA by the New Mexico Health Care Authority Division of Health Improvement (Health Facility Licensing & Certification). The HCA CLIA program page describes education and enforcement of the federal regulations (42 CFR Part 493). We found no separate general New Mexico clinical laboratory facility license on that page. Hospital laboratory services have additional rules in 8.370.12.31 NMAC. Section 8.370.17.32 NMAC applies to laboratory services in freestanding birth centers, which must hold an appropriate CLIA certificate; it is not a general personnel-licensing chapter for all clinical laboratories.

Last reviewed: November 20, 2026. Sources: New Mexico Health Care Authority: Clinical Laboratory Improvement Act program, New Mexico Health Care Authority: Division of Health Improvement, 8.370.17 NMAC (Requirements for Freestanding Birth Centers).

Book a free consultation

Map of New Mexico: New Mexico CLIA oversight by the Health Care Authority
New Mexico clinical laboratory oversight at a glance. Agency details from the CMS state agency list and official New Mexico sources.

Who regulates clinical laboratories in New Mexico?

The current CLIA survey agency is the New Mexico Health Care Authority (HCA), Division of Health Improvement (DHI), Health Facility Licensing & Certification. HCA's Division of Health Improvement page states that DHI certifies clinical laboratories operating in New Mexico for health and safety requirements. The CMS CLIA state agency list (revised September 2026) lists the program as Health Facility Licensing & Certification, 5300 Homestead Rd. NE, Suite 300, Albuquerque, NM 87110; phone (505) 222-8646; email CLIA.DHI@hca.nm.gov. Confirm the current phone and mailing details with the program, because CMS still lists an older nmhealth.org website and HCA now publishes the program at hca.nm.gov.

HCA's Clinical Laboratory Improvement Act program page says the program covers all laboratory facilities, including physician office laboratories, and that its purpose is education and enforcement of the federal regulations. Form CMS-116 and CLIA fees are linked from that page (CMS-116 and Pay.gov). Copies of electronic certificates are available through CMS QCOR.

We found no separate general New Mexico clinical laboratory facility license described on the HCA CLIA program page. Hospital facilities and freestanding birth centers have their own HCA facility licenses, and those chapters include laboratory-service rules in addition to CLIA.

Paperless CLIA certificates (March 1, 2026)

The HCA CLIA program page states that the CMS CLIA program has gone paperless as of March 1, 2026, and that paper fee coupons and certificates will no longer be furnished. To enroll for electronic notices, send an email to clia.dhi@hca.nm.gov that includes the facility name, the laboratory director's name, the CLIA number, and the email address that should receive notifications. HCA states that only one email may be enrolled per facility at this time. Look up existing electronic certificates in QCOR.

What 8.370.17 NMAC actually covers

The official text of 8.370.17 NMAC at the New Mexico State Records Center and Archives is titled Requirements for Freestanding Birth Centers. The issuing agency is the New Mexico Health Care Authority, Division of Health Improvement (effective 7/1/2024). The scope is freestanding birth centers; it does not apply to hospital labor and delivery services under a hospital license, births in a private residence by licensed midwives, or offices and treatment rooms of licensed private practitioners (8.370.17.2).

Section 8.370.17.32 (Laboratory services) requires a birth center that provides on-site laboratory services to meet current CLIA regulations and to hold a CLIA certificate appropriate to the level of testing (waiver, provider-performed microscopy, or moderate complexity, as applicable). A birth center that contracts laboratory work may only contract with a laboratory that meets CLIA and holds the right certificate. Results must be entered in the client record, procedures must follow acceptable standards of practice, and the rule lists basic physical requirements for counters, hand washing, storage and specimen collection. That section is a birth-center laboratory-services rule, not a statewide clinical laboratory personnel license.

If you operate a freestanding birth center laboratory, use both the birth-center license chapter and CLIA. If you operate any other clinical laboratory, do not treat 8.370.17.32 as your personnel chapter; use 42 CFR Part 493, Subpart M, and, in a licensed hospital, 8.370.12.31.

Hospital laboratory rules: 8.370.12.31 NMAC

8.370.12 NMAC (Requirements for Acute Care, Limited Services and Special Hospitals), issued by the New Mexico Health Care Authority and effective 7/1/2024, includes 8.370.12.31, Laboratory services. The rule requires laboratory services commensurate with the hospital's size and scope, either on site or by contract, and 24-hour emergency laboratory availability. A hospital that contracts laboratory services complies with that availability paragraph if the contracted laboratory has a current CLIA certificate at the appropriate level of testing.

Personnel language in 8.370.12.31(C) states that a qualified medical technologist shall be a graduate of a medical technology program approved by a nationally recognized body or have documented equivalent education, training or experience, and that a qualified medical lab technician shall be a graduate of a program approved by the federal health care authority and human services. The laboratory may not perform procedures and tests outside the scope of training of laboratory personnel. The laboratory director is responsible for the laboratory report, and the hospital must have a copy of its current CLIA certificate or verification of a contractor's current certificate.

Anatomical pathology services must be under the direct supervision of a pathologist. If pathology is provided on a consultative basis, the hospital must provide for, at minimum, monthly consultative visits by the pathologist, and the pathologist must be available in person or electronically at all times (8.370.12.31(E)). Emergency or disaster-related specimens may need referral to the Scientific Laboratory Division, and notifiable conditions are reported to the office of epidemiology and the local public health office, as that section requires.

These hospital-chapter rules sit on top of CLIA for licensed hospitals. They are not a general license for independent clinical laboratories or physician office laboratories.

Personnel: CLIA Subpart M, not a statewide MLS license

We found no separate New Mexico state license for medical laboratory scientists or other general clinical laboratory testing personnel. Federal CLIA personnel standards in 42 CFR Part 493, Subpart M, still apply, including director qualifications and the director's on-site visit rule (at least once every 6 months, visits at least 4 months apart, and no more than five laboratories; 42 CFR 493.1407). Hospital laboratories also follow the personnel language in 8.370.12.31. Confirm any facility-specific staffing rule with HCA for your license type.

CLIA certificate types

CertificateWho uses itInspection
Certificate of WaiverOnly FDA-waived testsNo routine survey; follow manufacturer instructions
Provider-Performed Microscopy (PPM)Physicians or mid-level practitioners doing specified microscopy, plus waived testsNo routine survey
Certificate of RegistrationNew moderate or high complexity labs until compliance is determinedLeads to Compliance or Accreditation
Certificate of ComplianceModerate or high complexity labs inspected by the state agencyState agency survey for CMS
Certificate of AccreditationModerate or high complexity labs accredited by a CMS-approved accreditorAccreditor inspection; CMS validation surveys possible

CLIA certificate fees (CMS fee schedule)

These are CMS fees, billed every two years and paid online at pay.gov after the state agency processes Form CMS-116. They are not Sound Lab Consultants fees. Source: CMS CLIA Certificate Fee Schedule (updated 2024).

Certificate or scheduleAnnual test volumeBiennial certificate fee (CMS)Compliance: average survey fee (CMS)Accreditation: average validation fee (CMS)
Certificate of WaiverAny (waived tests only)$248NoneNone
Provider-Performed Microscopy (PPM)Any$297NoneNone
Certificate of RegistrationNew Compliance or Accreditation lab$123NoneNone
Low volume2,000 or fewer$223$446$22
Schedule A (3 or fewer specialties)2,001 to 10,000$223$1,477$74
Schedule B (4 or more specialties)2,001 to 10,000$223$1,969$98
Schedule C (3 or fewer specialties)10,001 to 25,000$639$2,463$123
Schedule D (4 or more specialties)10,001 to 25,000$654$2,894$145
Schedule E25,001 to 50,000$966$3,325$166
Schedule F50,001 to 75,000$1,635$3,755$188
Schedule G75,001 to 100,000$2,304$4,187$209
Schedule H100,001 to 500,000$3,032$4,618$231
Schedule I500,001 to 1,000,000$9,244$5,049$252
Schedule JMore than 1,000,000$11,801$5,459 plus $411 per extra 500,000 tests$273 plus $21 per extra 500,000 tests
  • CMS fee schedule: replacement certificates cost $75 and revised certificates cost $95 (Waiver, Accreditation) or $150 (PPM, Registration, Compliance).
  • Accredited labs also pay their accreditor, whose fees CMS does not set.
  • Waived tests and quality control, quality assurance and proficiency testing runs do not count toward annual volume.

How to look up a New Mexico CLIA certificate in QCOR

CMS's Quality, Certification and Oversight Reports site (QCOR) lists active CLIA-certified labs, and CMS says labs can use it to access and reprint their CLIA certificate (CMS: Laboratory performance and QCOR certificate lookup).

  1. Open the CMS QCOR CLIA Laboratory Lookup page (CLIA Laboratory Lookup).
  2. Search by facility name, CLIA number, director, state (NM) or ZIP code, using * for missing digits (for example 871**).
  3. Check the certificate type, the testing address and the expiration date.
  4. Open the certificate link to view or print the current electronic certificate.

QCOR shows active labs only and is updated weekly. If a New Mexico record looks wrong, contact the Division of Health Improvement, Health Facility Licensing & Certification at CLIA.DHI@hca.nm.gov.

Planning a New Mexico lab or fixing a survey finding? Get a free review of your test menu, certificate path and staffing.

Book a free consultation

CLIA lab director and personnel roles

RoleWhen CLIA requires itRule
Laboratory directorEvery non-waived lab (moderate or high complexity)42 CFR 493.1405 (moderate), 493.1443 (high)
Technical consultantModerate complexity testing42 CFR 493.1411 and 493.1413
Technical supervisorHigh complexity testing, by specialty42 CFR 493.1449 and 493.1451
Clinical consultantModerate and high complexity42 CFR 493.1417 and 493.1455
General supervisorHigh complexity testing42 CFR 493.1461 and 493.1463
Testing personnelAnyone performing non-waived tests42 CFR 493.1423 (moderate), 493.1489 (high)

CMS revised the CLIA personnel rules effective December 28, 2024. High complexity directors who were qualified and serving in a CLIA-certified lab on that date, and have served continuously since, remain qualified (42 CFR 493.1443 (high complexity director)). A director may direct no more than five laboratories and must be on site at least once every 6 months, with at least 4 months between the two visits, and stay reachable for consultation (42 CFR 493.1407 for moderate complexity). Competency for testing staff is assessed twice in the first year on a test system and yearly after that.

Starting a new clinical lab

  1. Define the test menu and look up each test's FDA complexity (waived, moderate, high).
  2. Pick the CLIA certificate path: Waiver, PPM, or Registration followed by Compliance or Accreditation.
  3. Secure a qualified laboratory director and, for non-waived testing, a technical consultant or technical supervisors.
  4. Plan space, instruments, LIS and specimen flow; write the procedure manual and quality plan.
  5. File Form CMS-116 with the state agency, pay the CMS fee, and confirm the certificate before patient testing.
  6. Verify or validate every non-waived method, enroll in proficiency testing, train staff and document competency.
  7. Prepare for the first state agency survey or accreditation inspection.

For the full national checklist, see the pillar guide How to start a clinical laboratory.

How Sound Lab Consultants helps

  • New lab startup: certificate path, Form CMS-116, director and staffing plan, procedure manual and quality plan.
  • Method verification and validation plans and reports under 42 CFR 493.1253.
  • Proficiency testing enrollment, review and corrective action.
  • Mock inspections against CMS Appendix C, CAP, COLA or Joint Commission standards, and plans of correction after a CMS-2567.
  • Director and technical consultant qualification checks against Subpart M, plus state personnel license checks.
  • Sound Lab Consultants is an independent firm headquartered at 25 Arizona Pl, Chandler, AZ 85225. It serves labs remotely and through scheduled on-site visits, and is not affiliated with CMS, any state agency or any accreditor.

Method validation and verification

Before reporting patient results on a non-waived test, CLIA requires the lab to check method performance (42 CFR 493.1253 (method performance specifications)):

  • Unmodified FDA-cleared or approved tests: verify accuracy, precision, reportable range and that the manufacturer's reference intervals fit your patient population.
  • Modified FDA tests and laboratory developed tests: establish accuracy, precision, analytical sensitivity, analytical specificity, reportable range, reference intervals and any other needed characteristics.
  • Keep the plan, raw data, statistics and the director's signed approval together; surveyors ask for them.

Proficiency testing

Labs with a Certificate of Compliance or Certificate of Accreditation must enroll in a CMS-approved proficiency testing (PT) program for each regulated analyte they test (42 CFR Part 493, Subpart H (proficiency testing)).

  • Test PT samples the same way as patient samples, by the people who normally run the test.
  • Never send PT samples to another lab or discuss results with another lab before the reporting deadline.
  • Review every PT result, investigate any failure, and document the corrective action.
  • For tests without a PT program, verify accuracy at least twice a year by another method, such as split samples.

Surveys and deficiencies

  • Certificate of Compliance labs are surveyed by the state agency for CMS, generally on the two-year certificate cycle.
  • Certificate of Accreditation labs are inspected by their accreditor; CMS and the state agency can still do validation and complaint surveys.
  • Surveyors follow CMS State Operations Manual Appendix C (survey procedures and interpretive guidelines for laboratories).
  • Deficiencies are written on Form CMS-2567. The lab answers with a plan of correction that shows what was fixed, how, by whom and by when, and how it will stay fixed.

Accreditation options: POL, COLA, CAP, Joint Commission

A non-waived lab can be surveyed by the state agency (Certificate of Compliance) or by a CMS-approved accreditor (Certificate of Accreditation). CMS's approved list includes AABB, A2LA, ACHC, ASHI, CAP, COLA and The Joint Commission (CMS list of approved CLIA accreditation organizations).

  • Waived-only labs, including many physician office labs (POLs), use a Certificate of Waiver and need no accreditation.
  • Physician office and clinic labs doing moderate complexity testing often choose state agency surveys or COLA accreditation.
  • Hospital labs often align lab accreditation with the hospital's accreditor, such as The Joint Commission, or choose CAP.
  • Blood banks may add AABB; histocompatibility labs use ASHI or another accreditor approved for that specialty.
  • Sound Lab Consultants prepares labs for any of these options and is not affiliated with any accreditor.

Frequently asked questions

Does New Mexico require a separate state clinical laboratory license?

The HCA CLIA program page describes federal CLIA certification for laboratory facilities, including physician office laboratories. We found no separate general New Mexico clinical laboratory facility license on that page. Licensed hospitals and freestanding birth centers have additional laboratory-service rules in 8.370.12.31 and 8.370.17.32 NMAC.

Who is the CLIA state agency in New Mexico?

New Mexico Health Care Authority (HCA), Division of Health Improvement, Health Facility Licensing & Certification: 5300 Homestead Rd. NE, Suite 300, Albuquerque, NM 87110; phone (505) 222-8646; email CLIA.DHI@hca.nm.gov (CMS CLIA state agency list, revised September 2026). Official program page: https://www.hca.nm.gov/clinical-laboratory-improvement-act/. The current program page is on the New Mexico Health Care Authority website.

Is 8.370.17.32 the personnel standard for all New Mexico clinical labs?

No. The official text of 8.370.17 NMAC is Requirements for Freestanding Birth Centers. Section 8.370.17.32 requires birth-center laboratory services to meet CLIA and to hold an appropriate CLIA certificate. General clinical laboratory personnel standards are in 42 CFR Part 493, Subpart M. Hospital laboratories also follow personnel language in 8.370.12.31 NMAC.

Does New Mexico license medical laboratory scientists?

We found no separate statewide New Mexico license for medical laboratory scientists or general clinical laboratory testing personnel. CLIA Subpart M still applies. Hospital laboratories also use the medical technologist and medical lab technician language in 8.370.12.31 NMAC.

How do I get an electronic CLIA certificate in New Mexico?

HCA states that CMS CLIA became paperless on March 1, 2026. Email clia.dhi@hca.nm.gov with the facility name, laboratory director's name, CLIA number and the notification email (one email per facility). Look up certificates in CMS QCOR.

How often must a CLIA lab director be on site?

At least once every 6 months, with at least 4 months between the two visits, and the director must stay reachable for consultation (42 CFR 493.1407). A director may direct no more than five laboratories.

Is ISO 15189 the same as CLIA?

No. CLIA is the federal law for testing human specimens. ISO 15189 is an international standard for medical laboratory quality and competence that some labs adopt in addition to CLIA. Sound Lab Consultants supports ISO 15189; ISO/IEC 17025 applies to general testing and calibration labs.

How are lab consultants paid?

Usually hourly, by fixed project or monthly. Get a written scope with deliverables. Sound Lab Consultants quotes after a free consultation and does not publish prices.

Sources

Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225, is an independent consulting firm. It is not affiliated with CMS, any state agency or any accreditor, and it cannot grant certificates, licenses or accreditation. This page is educational and not legal advice.

Talk through your New Mexico lab.

Book a free consultation

Alabama

Alaska

Arizona

Arkansas

California

Colorado

Connecticut

Delaware

Florida

Georgia

Hawaii

Idaho

Illinois

Indiana

Iowa

Kansas

Kentucky

Louisiana

Maine

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Missouri

Montana

Nebraska

Nevada

New Hampshire

New Jersey

New Mexico

New York

North Dakota

Ohio

Oklahoma

Oregon

Pennsylvania

Rhode Island

South Carolina

South Dakota

Tennessee

Texas

Utah

Vermont

Virginia

Washington

West Virginia

Wisconsin

Wyoming

Moderate Complexity Lab Personnel Requirements

Testing Personnel

Technical Consultant

Clinical Consultant

Laboratory Director

Lab Facility Licensing Requirements

New Mexico CLIA Lab License Application

New Mexico CLIA FAQ

Does a New Mexico lab need a CLIA certificate?

Yes. New Mexico is not CLIA-exempt (only New York and Washington are). The CLIA program in the Health Care Authority's Division of Health Improvement checks that all lab facilities, including physician office laboratories, meet federal standards. Labs apply with Form CMS-116 and pay CLIA user fees through Pay.gov. See our CMS-116 application guide.

Are New Mexico CLIA certificates still mailed?

No. The CMS CLIA program went paperless on March 1, 2026, so paper fee coupons and certificates are no longer sent. The Health Care Authority asks labs to enroll an email address for notices by sending the facility name, laboratory director, CLIA number and email to the state CLIA program. Copies of current certificates are available through CMS QCOR.

What does New Mexico require from the laboratory director?

For PPM, Compliance and Accreditation certificates, the director must meet the education, training and experience rules in 42 CFR 493 subpart M, and proof of those qualifications goes in with Form CMS-116.

Does New Mexico license laboratory personnel?

No. New Mexico is not one of the states with clinical laboratory personnel licensure, so staff qualifications are set by federal CLIA by test complexity.

What personnel does a moderate complexity lab in New Mexico need?

Under federal CLIA, a laboratory director, clinical consultant, technical consultant and qualified testing personnel. New Mexico adds no separate personnel license on top of these CLIA roles.

Related: free CLIA readiness check, how to start a clinical lab, all state licensing pages.

Opening or upgrading a lab in New Mexico?

Book a free consultation

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.