Short answer: CLIA regulations are in 42 CFR Part 493, Laboratory Requirements, which CMS uses to certify and oversee U.S. labs that test human specimens. Subparts A to F cover scope, test complexity, certificates, accreditation, exempt states and fees. H to M add PT, facility, quality system and personnel rules for nonwaived testing. Q, R and T cover inspection, enforcement and CLIAC.
Last reviewed: November 22, 2026. Primary sources: eCFR, 42 CFR Part 493, Laboratory Requirements, GovInfo, 42 CFR Part 493 (Oct. 1, 2025 edition, PDF), CMS, Clinical Laboratory Improvement Amendments (CLIA), FDA, CLIA, CDC, CLIA: About, Federal Register, CMS-3326-F (Dec. 28, 2023).
What 42 CFR Part 493 is
Part 493 of Title 42 of the Code of Federal Regulations is where the federal government turned the Clinical Laboratory Improvement Amendments of 1988 into working rules. The statute is 42 U.S.C. 263a; Part 493 is the regulation CMS issues to carry it out, and it is titled simply "Laboratory Requirements" (CDC). Section 493.1 says the part sets the conditions every laboratory must meet to be certified to test human specimens, and that the same requirements apply whether a lab wants a CLIA certificate or Medicare approval.
The rules reach any facility that examines material from the human body to give information for diagnosing, preventing or treating disease, or for assessing health. That is why a small physician office running urine dipsticks and a reference lab running next-generation sequencing answer to the same Part. What changes between them is how much of Part 493 applies, and that is decided by test complexity (CMS).
Section 493.3 lists what falls outside the rules: testing done only for forensic purposes, research labs that do not report patient-specific results for diagnosis or treatment, and drug testing by SAMHSA-certified labs that meets SAMHSA rules (other testing in those labs is still covered). Federal agency labs are covered, though HHS may modify how the rules apply to them. CMS estimates CLIA covers about 320,000 laboratory entities (CMS).
Which text to read. The eCFR is updated continuously but is not the official legal edition. The official annual CFR is published each October on GovInfo. Changes first appear as rules in the Federal Register. Surveyors interpret the text using CMS State Operations Manual Appendix C.
Key subparts of 42 CFR Part 493
Part 493 is split into lettered subparts. Several letters (G, L, N to P and S) are reserved and hold no text, and the part ends at Subpart T. The sections below follow the order of the regulation.
Subpart A: General provisions (493.1 to 493.25)
Subpart A defines the vocabulary and sorts every test into a complexity category. Key sections:
- 493.1 basis and scope, and 493.2 definitions, including "condition level requirements", "immediate jeopardy", "unsuccessful participation in proficiency testing" and "waived test".
- 493.3 applicability and the forensic, research and SAMHSA exceptions.
- 493.5 three categories: waived tests, moderate complexity (which includes provider-performed microscopy, PPM) and high complexity. A lab may run any mix, and must either be CLIA-exempt or hold one of five certificates.
- 493.15 waived tests: simple tests cleared for home use, methods so simple and accurate that errors are unlikely, or tests that pose no reasonable risk of harm if done wrong. It also lists the tests the rule itself names as waived, such as non-automated dipstick urinalysis and visual urine pregnancy tests.
- 493.17 the scoring system. Each test is scored 1, 2 or 3 on seven criteria; a total of 12 or less is moderate complexity and above 12 is high complexity. A test not yet categorized is treated as high complexity until it is reviewed.
- 493.19 PPM criteria (microscopy personally performed by a physician, qualified midlevel practitioner or dentist during the patient visit), plus 493.20 and 493.25, which point moderate and high complexity labs to the subparts they must meet.
Subparts B to D: CLIA certificates (493.35 to 493.63)
These three subparts set up the five certificate types. Waiver, PPM, registration and compliance certificates are each valid for no more than two years, and labs must tell CMS or its agent about changes such as ownership, name, location or director within 30 days.
- Subpart B, Certificate of Waiver (493.35 to 493.41). Application, requirements, notification duties and the condition at 493.41 on reporting SARS-CoV-2 results, which is tied to the COVID-19 Public Health Emergency definition. A waived lab that adds nonwaived tests must move to a Subpart C or D certificate.
- Subpart C, Registration Certificate, PPM Certificate and Certificate of Compliance (493.43 to 493.53). A new nonwaived lab first gets a registration certificate, which lasts until a compliance inspection or two years, whichever is shorter. After an initial survey finds the lab in compliance, it receives a Certificate of Compliance. PPM is a certificate in this subpart, not a subpart of its own.
- Subpart D, Certificate of Accreditation (493.55 to 493.63). The path for labs inspected by a CMS-approved accreditation organization instead of the State Agency.
Compare the options in CLIA certificate types and test complexity, Certificate of Waiver requirements, the PPM certificate and Certificate of Compliance vs Accreditation.
Subpart E: Accreditation and state exemption (493.551 to 493.575)
Subpart E lets CMS grant "deemed status" to accredited labs and exempt every licensed lab in a state with an approved licensure program. Under 493.551, the accreditor's or state's rules must be equal to or more stringent than CLIA condition-level requirements. Later sections cover the approval process, federal review, validation inspections, disclosure of results, ongoing federal oversight and removal of deeming authority or exemption at 493.575. An approved state program must reapply every two years.
CMS's current list names two CLIA-exempt states: Washington (Medical Test Site Program) and New York (Clinical Laboratory Evaluation Program) (CMS exempt states list, Aug. 2025, PDF). Accredited labs must still meet Subpart H PT rules, pay Subpart F fees and let their PT provider share results with the accreditor. See CLIA exempt states.
Subpart F: General administration and fees (through 493.680)
Subpart F holds the money rules. It opens with scope and applicability sections, then sets certificate fees at 493.638 (set biennially by HHS, with waiver and PPM fees based on test category), fees for revised and replacement certificates at 493.639, compliance determination fees for Certificate of Compliance labs at 493.643, additional fees for accredited, waived and PPM labs at 493.645, state program fees at 493.649, payment at 493.655 and the biennial increase method at 493.680.
In practice CMS is now paperless: it no longer mails paper certificates or fee coupons, does not accept paper checks and takes fees online through pay.gov. Labs applying for an initial certificate or updating certificate information must use the revised Form CMS-116 starting November 9, 2026 (CMS). Current amounts are on CLIA certificate fees; the application steps are in the CMS-116 application guide.
Subpart G: Reserved
Subpart G holds no text today. Some summaries place PPM here, but PPM rules sit in Subparts A (493.5, 493.19), C (the PPM certificate) and M (PPM director and testing personnel). Note that the 493.2 definition of condition-level requirements still refers to "subparts G through Q", so the letter range shows up even though G itself is empty.
Subparts H and I: Proficiency testing (493.801 to 493.959)
Subpart H applies to labs doing moderate or high complexity testing. Under 493.801 a lab must enroll in an HHS-approved PT program for each specialty and subspecialty it is certified for, stay with a chosen program for at least a year before switching, and test PT samples like patient specimens: same staff, same methods, same number of runs. Labs may not discuss PT results with other labs before the reporting deadline and may not send PT samples out. A lab that CMS finds intentionally referred PT samples can lose its certificate for at least one year (493.1840).
"Unsuccessful participation" means, among other things, failing the same analyte in two consecutive events or two out of three (493.2). 493.803 sets the successful-participation condition, 493.807 reinstatement, and 493.821 to 493.865 the specialty conditions and standards, from bacteriology through antibody identification.
Subpart I is written for PT providers. 493.901 and 493.903 cover approval and administration, and 493.909 to 493.959 list the regulated analytes and grading criteria by specialty. For example, an approved bacteriology program must send at least five samples per event and at least three events a year (493.911). Tests not listed in Subpart I still need twice-yearly accuracy checks under 493.1236(c). Details: lab proficiency testing requirements and PT referral rules.
Subpart J: Facility administration (493.1100 to 493.1105)
Subpart J is short but often cited. 493.1100 is the condition (it also carries the SARS-CoV-2 result reporting tied to the Public Health Emergency); 493.1101 requires space, ventilation and utilities for every phase of testing, controls on contamination, a one-way workflow with separate areas for molecular amplification that is not in a closed system, enough equipment and supplies, safety procedures and proper storage of records and materials; 493.1103 sets duties for facilities that provide transfusion services, such as a transfusion service agreement and prompt ABO, D(Rho), antibody and compatibility testing through a CLIA-certified lab.
493.1105 sets record retention. The baseline is at least two years for requisitions, discontinued procedures, QC and patient test records, PT records, quality assessment records and test reports, with longer periods for some records: pathology reports at least 10 years, cytology slides at least 5 years, histopathology slides at least 10 years, and immunohematology records as set by FDA rules at 21 CFR 606.160. See CLIA record retention requirements.
Subpart K: Quality system for nonwaived testing (493.1200 to 493.1299)
Subpart K is the largest operational subpart. 493.1200 requires written policies and procedures that run and monitor a quality system across the whole testing process. It is built in four blocks, plus specialty conditions at 493.1201 to 493.1227 that tell each specialty which standards apply.
| Block | Sections | What labs must show |
|---|---|---|
| General laboratory systems | 493.1230 to 493.1239 | Patient confidentiality, specimen identification and integrity, complaint investigations, communications, competency policies, PT evaluation and quality assessment |
| Preanalytic systems | 493.1240 to 493.1249 | Written or electronic test requests from an authorized person, specimen submission, handling and referral rules, preanalytic quality assessment |
| Analytic systems | 493.1250 to 493.1289 | Procedure manual (493.1251), reagents and equipment, verifying or establishing performance specifications before reporting (493.1253), maintenance, calibration verification at least every 6 months (493.1255), daily controls including two levels for each quantitative test (493.1256), corrective action and test records |
| Postanalytic systems | 493.1290 to 493.1299 | Test report contents such as patient ID, lab name and address, report date, test, specimen source when relevant and result with units (493.1291), plus postanalytic quality assessment |
Unmodified FDA-cleared tests need verification of accuracy, precision, reportable range and reference intervals. Modified tests and lab-developed methods must establish more, including analytical sensitivity and specificity (493.1253). Deep dives: CLIA quality control requirements, IQCP, laboratory quality management systems and test requisition and report rules.
Subpart M: Personnel for nonwaived testing (493.1351 to 493.1495)
Subpart M lists qualifications and duties by role and by complexity. Waived-only labs have no Subpart M personnel requirements.
| Testing level | Required roles | Sections |
|---|---|---|
| PPM | Laboratory director, testing personnel | 493.1355 to 493.1365 |
| Moderate complexity | Laboratory director, technical consultant, clinical consultant, testing personnel | 493.1403 to 493.1425 |
| High complexity | Laboratory director, technical supervisor, clinical consultant, general supervisor, cytology general supervisor, cytotechnologist, testing personnel | 493.1441 to 493.1495 |
Two director rules come up in nearly every survey. A person may direct no more than five laboratories, and since December 28, 2024 moderate and high complexity directors must be on site at least once every six months, with at least four months between the two visits, and must document them (493.1407, 493.1445). Staff competency must be assessed at least twice in an employee's first year of patient testing and at least yearly after that. See CLIA personnel qualifications, CLIA lab director responsibilities and the CLIA technical consultant role.
Subparts Q and R: Inspection and enforcement (493.1771 to 493.1850)
Subpart Q requires every lab to let CMS or its agent inspect (493.1771, 493.1773). Surveyors may ask the lab to test samples, interview staff, watch all phases of testing, enter every area under the certificate and copy records. Waived and PPM labs are not on a biennial cycle but can be inspected for complaints, risk or tests outside their certificate (493.1775). Certificate of Compliance labs get an initial survey and then surveys on a biennial basis or more often (493.1777). Accredited and exempt-state labs face CMS validation and complaint inspections (493.1780).
Subpart R covers what happens when a lab fails a condition. The principal sanctions are suspension, limitation or revocation of the certificate. Alternative sanctions are a directed plan of correction, state onsite monitoring and civil money penalties (493.1806). CMS can also cancel Medicare approval, suspend Medicare payments, sue to stop hazardous activity, and seek criminal penalties for intentional violations. When deficiencies pose immediate jeopardy, CMS acts faster (493.1812). Appeals are at 493.1844, and CMS compiles a laboratory registry for each prior calendar year under 493.1850. More: how to prepare for a CLIA survey, CMS-2567 plan of correction, condition-level deficiencies and sanctions and immediate jeopardy.
Not sure which subparts your test menu triggers? Get it mapped section by section.
Subpart T: Consultations (493.2001)
Subpart T has a single section, 493.2001, which sets up the Clinical Laboratory Improvement Advisory Committee (CLIAC). CLIAC advises HHS on technical and scientific parts of Part 493, including test categorization criteria, and must meet at least once a year. CDC manages the committee, and CMS, CDC and FDA sit on it as ex officio members (CDC CLIAC). See CLIAC explained.
Subpart summary table
| Subpart | Title (short) | Sections | Who it mainly affects |
|---|---|---|---|
| A | General provisions | 493.1 to 493.25 | All labs |
| B | Certificate of Waiver | 493.35 to 493.41 | Waived-only labs |
| C | Registration, PPM and Compliance certificates | 493.43 to 493.53 | PPM labs and State Agency-surveyed nonwaived labs |
| D | Certificate of Accreditation | 493.55 to 493.63 | Accredited nonwaived labs |
| E | Accreditation organizations and exempt state programs | 493.551 to 493.575 | Accreditors, NY and WA programs, labs they oversee |
| F | General administration (fees) | Scope sections, then 493.638 to 493.680 | All certificate holders |
| G | Reserved | None | None |
| H | PT participation for nonwaived testing | 493.801 to 493.865 | Moderate and high complexity labs |
| I | PT programs for nonwaived testing | 493.901 to 493.959 | PT providers; labs reading PT grades |
| J | Facility administration | 493.1100 to 493.1105 | Nonwaived labs |
| K | Quality system | 493.1200 to 493.1299 | Nonwaived labs |
| L | Reserved | None | None |
| M | Personnel | 493.1351 to 493.1495 | PPM, moderate and high complexity labs |
| N to P | Reserved | None | None |
| Q | Inspection | 493.1771 to 493.1780 | All labs, including exempt-state labs |
| R | Enforcement procedures | 493.1800 to 493.1850 | Labs with condition-level deficiencies |
| S | Reserved | None | None |
| T | Consultations (CLIAC) | 493.2001 | HHS advisory process |
Agency roles: CMS, FDA and CDC
Three HHS agencies run the CLIA program, each with a separate job (FDA; CDC).
| Agency | Main CLIA duties |
|---|---|
| CMS | Issues certificates, collects user fees, inspects and enforces, approves accreditors, exempt states and PT programs, monitors PT results and publishes CLIA rules and guidance. State Survey Agencies do most inspections on its behalf. |
| FDA | Assigns each commercial test a complexity category, reviews CLIA Waiver by Application requests and writes the rules and guidance for categorization. Look up tests in the FDA CLIA database. |
| CDC | Provides research, analysis and technical help, develops technical standards and practice guidelines (including for cytology), runs quality improvement studies, monitors PT practices, produces education and manages CLIAC. |
Under 493.17, FDA categorizes commercial tests as part of 510(k) or PMA review, while CDC categorizes tests that are not commercially available when asked. More: CMS, FDA and CDC roles in CLIA, FDA CLIA categorization and CLIA Waiver by Application.
Requirements by test complexity
CMS puts it plainly: the more complicated the test, the stricter the rules. The table shows which Part 493 requirements apply at each level.
| Requirement | Waived | PPM | Moderate complexity | High complexity |
|---|---|---|---|---|
| Certificate | Certificate of Waiver (Subpart B) | PPM certificate (Subpart C) | Registration, then Compliance (C) or Accreditation (D) | Registration, then Compliance (C) or Accreditation (D) |
| Fees (Subpart F) | Yes | Yes | Yes, plus compliance or validation fees | Yes, plus compliance or validation fees |
| Follow manufacturer instructions | Yes (493.15(e)) | Yes | Yes | Yes |
| Proficiency testing (Subpart H) | No | Applicable Subpart H rules (493.47(c)) | Yes, for regulated analytes | Yes, for regulated analytes |
| Facility rules (Subpart J) | No | Applicable rules (493.47(c)) | Yes | Yes |
| Quality system (Subpart K) | No | Applicable rules (493.47(c)) | Yes | Yes |
| Personnel (Subpart M) | No | Director and testing personnel | Director, technical consultant, clinical consultant, testing personnel | Director, technical supervisor, clinical consultant, general supervisor, testing personnel (plus cytology roles) |
| Routine inspection (Subpart Q) | No biennial survey; complaint or risk visits | No biennial survey; complaint or risk visits | Biennial survey or accreditor inspection | Biennial survey or accreditor inspection |
| Enforcement (Subpart R) | Yes | Yes | Yes | Yes |
See waived testing compliance and pharmacy CLIA waiver for waived sites.
Which subparts apply to your lab
- List every test on your menu and look up each one's FDA category. Treat any test you modified or built in-house as high complexity unless it has been categorized.
- Pick the certificate for your highest-complexity test: waiver, PPM, or registration followed by Compliance or Accreditation.
- Check whether you are in New York or Washington; if so, the state program applies in place of most direct federal oversight.
- If you run any nonwaived test, add Subparts H, J, K and M to your compliance plan, plus Q and R for surveys and enforcement.
- Match your specialties to the Subpart K condition for each one and to the Subpart I analyte list for PT.
- Track rule changes in the Federal Register and CMS notices, and re-check your plan whenever you add tests, sites or staff.
A full self-check is on the CLIA compliance checklist, and an outside review is described on CLIA compliance audit.
Conditions vs standards
Part 493 labels many sections "Condition" or "Standard", and the label matters. A condition is a broad requirement, such as "Condition: Analytic systems" at 493.1250. Standards are the detailed rules under it, such as control procedures at 493.1256. Section 493.2 defines condition-level requirements as the conditions in 493.41 and Subparts G through Q, and a condition-level deficiency as failing one or more of them.
Standard-level findings usually lead to a plan of correction. Condition-level findings expose the lab to the Subpart R sanctions above, and immediate jeopardy findings add urgency. See CLIA D-tags and CLIA alternative sanctions.
Recent amendments to Part 493
| Rule | Published | What changed | Effective |
|---|---|---|---|
| CMS-3355-F, 87 FR 41194 | July 11, 2022 | Updated PT regulated analytes and acceptance limits in Subparts H and I, and aligned PT referral language with the statute | Most PT changes July 11, 2024; other parts Aug. 10, 2022 |
| CMS-3326-F, 88 FR 89976 | Dec. 28, 2023 | Biennial two-part fee increase and new limited fees; histocompatibility updates; personnel qualification and director duty changes; alternative sanctions for Certificate of Waiver labs (493.1804(c)) | Jan. 27, 2024; personnel and histocompatibility parts Dec. 28, 2024 |
| CMS-3478-P, 91 FR 64480 (proposed) | Oct. 8, 2026 | Would allow virtual access under the primary lab's certificate (not cytology), digital images for gynecologic cytology PT, and changes to personnel, SARS-CoV-2 reporting, certificates, test reports, enforcement and public consultation | Not final; comments due Dec. 7, 2026 |
Timeline and action steps: CLIA rule changes 2024 to 2026, 2024 personnel rule changes and the 2026 proposed rule.
How Sound Lab Consultants helps
Sound Lab Consultants works with labs across the United States on CLIA compliance for every CLIA specialty and subspecialty, from waived sites to high complexity molecular, immunohematology and anatomic pathology labs.
- Maps your test menu to the Part 493 subparts, certificate type and specialty conditions that apply.
- Builds or audits Subpart K procedures, QC, calibration verification and performance specification files.
- Checks Subpart M personnel files and director onsite records against the post-2024 text.
- Sets up PT enrollment and investigates unsatisfactory PT results under Subparts H and I.
- Runs mock surveys based on Subpart Q and Appendix C, and drafts plans of correction for CMS-2567 findings.
- Supports certificate applications, changes and accreditation choices under Subparts B to F.
- Helps manufacturers with FDA test categorization, CLIA Waiver by Application and Dual 510(k) submissions.
Get a clear, section-by-section plan for meeting 42 CFR Part 493.
Frequently asked questions
What is 42 CFR Part 493?
It is the federal regulation that carries out CLIA. Titled Laboratory Requirements, it sets certification, proficiency testing, quality system, personnel, inspection and enforcement rules for labs that test human specimens.
What are the subparts of 42 CFR 493?
The active subparts are A (general provisions), B, C and D (certificates), E (accreditation and exempt states), F (fees), H and I (proficiency testing), J (facility administration), K (quality system), M (personnel), Q (inspection), R (enforcement) and T (CLIAC). G, L, N to P and S are reserved.
Is there a Subpart G or Subpart U in Part 493?
Subpart G is reserved and has no text. There is no Subpart U; the part ends with Subpart T, section 493.2001.
Who issues and enforces 42 CFR Part 493?
CMS issues the regulation and enforces it through certificates, inspections and sanctions, mostly using State Survey Agencies and CMS-approved accreditors. FDA categorizes test complexity and CDC provides standards, research and CLIAC support.
Which subpart covers proficiency testing?
Subpart H sets the rules labs must follow when they enroll in and perform PT for nonwaived testing. Subpart I sets the standards PT programs must meet to be approved, including the regulated analytes and grading criteria.
Which subpart covers quality control?
Subpart K, the quality system for nonwaived testing. Control procedures are at 493.1256, calibration and calibration verification at 493.1255, and performance specifications at 493.1253.
Which subpart covers personnel and lab director rules?
Subpart M, sections 493.1351 to 493.1495. It sets qualifications and duties for PPM, moderate complexity and high complexity roles, including the five-lab limit and the twice-yearly onsite visit rule for directors.
Do waived labs have to follow all of Part 493?
No. Waived-only labs need a Certificate of Waiver, must pay fees, follow manufacturer instructions, allow inspections and are subject to enforcement. Subparts H, J, K and M do not apply to waived testing.
How is test complexity decided under Part 493?
Section 493.17 scores each test from 1 to 3 on seven criteria. A total of 12 or less is moderate complexity and above 12 is high complexity. Waived tests meet the separate criteria in 493.15.
What is the difference between a condition and a standard?
A condition is a broad requirement, such as analytic systems; standards are the detailed rules under it. Failing a condition is a condition-level deficiency and can lead to Subpart R sanctions.
Which states are exempt from CLIA?
CMS lists Washington and New York as states with approved licensure programs, so labs licensed there are exempt from most direct CLIA requirements under Subpart E. They are still subject to federal validation and complaint inspections.
How long must CLIA records be kept?
Under 493.1105, most records, including requisitions, QC, PT, quality assessment and test reports, must be kept at least two years. Some immunohematology, pathology and cytology records must be kept longer.
What changed in Part 493 in 2024?
PT analyte and acceptance-limit changes took effect July 11, 2024. CMS-3326-F fee changes took effect January 27, 2024, and its personnel and histocompatibility changes took effect December 28, 2024.
Where can I read the official text of 42 CFR 493?
The eCFR shows the current text, updated continuously. The official annual edition is on GovInfo, and new amendments appear first in the Federal Register.
Official sources
- eCFR, 42 CFR Part 493, Laboratory Requirements
- GovInfo, 42 CFR Part 493, Oct. 1, 2025 edition (PDF)
- 42 U.S.C. 263a, Certification of laboratories (GovInfo)
- CMS, Clinical Laboratory Improvement Amendments (CLIA)
- CMS, List of exempt states under CLIA (Aug. 2025, PDF)
- CMS State Operations Manual, Appendix C (PDF)
- FDA, Clinical Laboratory Improvement Amendments (CLIA)
- FDA, CLIA test categorization database
- CDC, Clinical Laboratory Improvement Amendments: About
- CDC, CLIAC: About
- Federal Register, CMS-3355-F, CLIA PT regulations related to analytes and acceptable performance (July 11, 2022)
- Federal Register, CMS-3326-F, CLIA fees; histocompatibility, personnel and alternative sanctions for CoW labs (Dec. 28, 2023)
- Federal Register, CMS-3478-P, CLIA virtual access, gynecologic cytology PT, personnel qualifications and other changes, proposed rule (Oct. 8, 2026)
Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the U.S. Department of Health and Human Services, any state survey agency, the College of American Pathologists, COLA, The Joint Commission, AABB, ACHC, ASHI, A2LA or any other accrediting organization or Medicare contractor. This page is general regulatory information, not legal, billing or medical advice. Confirm current requirements with the agency or accreditor that oversees your laboratory. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.