CLIA Test Requisition and Test Report Requirements
CLIA requires a lab to test only on the written or electronic request of an authorized person and to capture specific information on the requisition (42 CFR 493.1241). The test report must include the patient identifier, the name and address of the lab that performed the test, the report date, the test performed, specimen source when appropriate, results with units, and specimen condition problems (42 CFR 493.1291). Requisition and report templates should be designed so these fields cannot be skipped.
Last reviewed: Oct 31, 2026
Requisition checklist (493.1241)
- Name and address or other identifier of the authorized person requesting the test and, if appropriate, the person responsible for using the results.
- Patient name or unique identifier.
- Sex and age or date of birth.
- Test or tests to be performed.
- Source of the specimen, when appropriate.
- Date and, if appropriate, time of specimen collection.
- Any additional information relevant and necessary for a specific test to ensure accurate and timely testing and reporting.
- A written process for oral requests, including soliciting written or electronic authorization within 30 days.
- A check that requested tests are transcribed or entered accurately.

Test report checklist (493.1291)
- Patient name and identification number, or a unique patient identifier.
- Name and address of the laboratory location where the test was performed.
- Test report date.
- Test performed and specimen source, when appropriate.
- Test result and units of measurement or interpretation, if applicable.
- Information on specimen condition and disposition when it does not meet acceptability criteria.
- Reference intervals or normal values available to the authorized person.
- A process for critical values, corrected reports and reports from referral labs.
- Release only to authorized persons, and to the patient or their representative on request as 493.1291(l) allows.
Design tips for molecular, toxicology and panel reports
- List every target or analyte tested, not only positives, so a negative result is interpretable.
- Show cutoffs or limits of detection where the result is reported against them.
- State method limitations and whether a result is presumptive or confirmed.
- For laboratory-developed tests, include any statement your accreditor requires.
- Keep interpretive comments consistent with the validated performance; do not add claims the validation did not establish.
Common survey problems
- Reports missing the performing lab's address, often when testing is sent out.
- Requisitions without patient date of birth or collection date.
- Oral orders with no written follow-up.
- Corrected reports that do not identify the change or are not sent to the original recipient.
- Interface or EHR displays that drop units or reference intervals; see EMR result interface verification.
Records to keep
- Requisitions (paper or electronic) and test reports for at least the 493.1105 periods.
- Corrected report records and notifications.
- Interface verification records showing report content displays correctly.
- Form version history and approval.
How Sound Lab Consultants helps
We review and redesign requisition and report templates, check interface displays and add preanalytic and postanalytic monitors to the QA plan. See CLIA quality assessment plan and laboratory SOP writing.
Frequently asked questions
What must be on a CLIA test requisition?
The requester's identifier, patient name or ID, sex and age or date of birth, tests requested, specimen source when appropriate, collection date and time when appropriate, and other information needed for the test. Source: 42 CFR 493.1241 Test request (eCFR).
Can a lab accept an oral test order?
Yes, but the lab must request written or electronic authorization within 30 days. Source: 42 CFR 493.1241 Test request (eCFR).
What must a CLIA test report include?
Patient ID, the performing lab's name and address, report date, test performed, specimen source when appropriate, result and units, and specimen condition information when relevant. Source: 42 CFR 493.1291 Test report (eCFR).
Can patients get their lab reports directly?
Yes. CLIA allows release of completed test reports to the patient or their personal representative on request. Source: 42 CFR 493.1291 Test report (eCFR).
How long are requisitions and reports kept?
At least two years for most records under 42 CFR 493.1105; some specialties are longer. Source: 42 CFR 493.1105 Retention requirements (eCFR).
Sources
- 42 CFR Part 493 (eCFR)
- 42 CFR 493.1241 Test request (eCFR)
- 42 CFR 493.1291 Test report (eCFR)
- 42 CFR 493.1299 Postanalytic systems quality assessment (eCFR)
- 42 CFR 493.1105 Retention requirements (eCFR)
- CMS State Operations Manual Appendix C (PDF)