CLIA Specialties and Subspecialties

CLIA groups nonwaived testing into specialties and subspecialties, each with a condition in 42 CFR 493 Subpart K (493.1201-493.1227) and, for many, PT standards in Subpart H. They are microbiology (bacteriology, mycobacteriology, mycology, parasitology, virology), diagnostic immunology (syphilis serology, general immunology), chemistry (routine chemistry, urinalysis, endocrinology, toxicology), hematology, immunohematology, pathology (histopathology, oral pathology, cytology), radiobioassay, histocompatibility and clinical cytogenetics. Labs list their specialties on Form CMS-116. Sound Lab Consultants works with labs in all of them.

Last reviewed: Oct 31, 2026

Book a free consultation

Abstract illustration of colored bars in rows representing many lab disciplines (no people, logos or text)

Specialty and subspecialty table

SpecialtySubspecialtyConditionSpecific QC standardPT standard (Subpart H)SLC page
MicrobiologyBacteriology493.1201493.1261493.823/clinical-microbiology-lab-consulting
MicrobiologyMycobacteriology493.1202493.1262493.825/clinical-microbiology-lab-consulting
MicrobiologyMycology493.1203493.1263493.827/clinical-microbiology-lab-consulting
MicrobiologyParasitology493.1204493.1264493.829/clinical-microbiology-lab-consulting
MicrobiologyVirology493.1205493.1265493.831/clinical-microbiology-lab-consulting
Diagnostic immunologySyphilis serology493.1207General (493.1256)493.835/diagnostic-immunology-syphilis-serology-lab-compliance
Diagnostic immunologyGeneral immunology493.1208General (493.1256)493.837/diagnostic-immunology-syphilis-serology-lab-compliance
ChemistryRoutine chemistry493.1210493.1267 (blood gas)493.841/clinical-chemistry-lab-consulting
ChemistryUrinalysis493.1211GeneralNone listed/urinalysis-lab-clia-compliance
ChemistryEndocrinology493.1212General493.843/endocrinology-lab-clia-compliance
ChemistryToxicology493.1213General493.845/how-to-start-a-toxicology-lab
HematologyHematology, including coagulation493.1215493.1269493.851/hematology-coagulation-lab-consulting
ImmunohematologyABO/D typing, antibody detection and identification, compatibility493.1217493.1271493.859-493.865/immunohematology-blood-bank-consulting
PathologyHistopathology493.1219493.1273None listed/histology-lab-setup-compliance
PathologyOral pathology493.1220GeneralNone listed/oral-pathology-lab-clia-compliance
PathologyCytology493.1221493.1274493.855 (gynecologic)/cytology-lab-clia-requirements
Radiobioassay-493.1226GeneralNone listed/radiobioassay-lab-clia-compliance
Histocompatibility-493.1227493.1278None listed/histocompatibility-hla-lab-consulting
Clinical cytogenetics-493.1225493.1276None listed/clinical-cytogenetics-lab-consulting

Where NGS and molecular testing fit

CLIA has no molecular or NGS specialty. A molecular test is assigned to the specialty for what it detects, such as microbiology for pathogen PCR, clinical cytogenetics for chromosomal microarray, histocompatibility for HLA typing, or pathology and chemistry for other analytes. Most NGS assays are laboratory-developed, so labs establish performance specifications under 493.1253(b)(2). See NGS Laboratory Validation and Consulting, NGS Report Generation and Bioinformatics Pipeline Validation and our NGS consultant page.

Blood banking and transfusion

Immunohematology testing is one specialty, but facilities that transfuse blood also meet the transfusion service standard in 493.1103 and the FDA blood rules that 493.1271 references, including 21 CFR 606. See Immunohematology and Blood Bank Consulting and Transfusion Service and Pre-Hospital Whole Blood Compliance.

Listing specialties on CMS-116

  • List every specialty and subspecialty the lab performs, with annual test volume estimates.
  • Adding a specialty later requires notifying CMS or the state agency; compliance-certificate labs follow the timelines in 493.51.
  • PT enrollment should match the specialties listed.
  • Personnel qualifications, especially technical supervisors in high complexity labs, are specialty-specific under 493.1449.

See our CMS-116 CLIA application guide.

Rules shared by every specialty

All specialties rely on the Subpart K general, preanalytic, analytic and postanalytic systems: procedure manuals (493.1251), performance specifications (493.1253), calibration (493.1255), controls (493.1256), comparison of results (493.1281), corrective action (493.1282), test records (493.1283) and test reports (493.1291). Where Subpart H lists no regulated analytes, 493.1236(c) requires verifying accuracy at least twice a year. Record retention in 493.1105 is at least 2 years for most records, with 10 years for pathology reports and histopathology slides, 5 years for cytology slides and FDA-specified periods for immunohematology records.

How to use this list

  1. Map each test on your menu to its specialty and complexity.
  2. Confirm the CLIA certificate and CMS-116 list every specialty.
  3. Check the specialty-specific QC section, if any, and the PT standard.
  4. Confirm the director and supervisors qualify for each specialty under Subpart M.
  5. Build SOPs, validation records and competency programs specialty by specialty.

How SLC helps

Sound Lab Consultants works with laboratories in this specialty remotely and on site as scheduled: gap reviews against the cited regulations, SOP and form writing, validation and verification plans, QC and PT program design, personnel file reviews and survey preparation. SLC consults; testing, diagnosis and medical decisions stay with the laboratory and its director. See the full CLIA specialties and subspecialties list and our CLIA consultant and clinical laboratory consulting services.

Frequently asked questions

How many CLIA specialties are there?

Subpart K lists conditions for microbiology (5 subspecialties), diagnostic immunology (2), chemistry (4), hematology, immunohematology, pathology (histopathology, oral pathology, cytology), radiobioassay, histocompatibility and clinical cytogenetics. Source: 42 CFR Part 493 Subpart K - Quality System for Nonwaived Testing (eCFR).

Is molecular diagnostics a CLIA specialty?

No. Molecular tests are categorized under the specialty for the analyte or organism detected. Source: 42 CFR Part 493 Subpart K - Quality System for Nonwaived Testing (eCFR), CMS-116 CLIA Application for Certification.

Where do I list specialties?

On Form CMS-116, the CLIA application. Source: CMS-116 CLIA Application for Certification.

Does every specialty have PT?

No. Subpart H lists regulated analytes for many specialties; others rely on twice-yearly accuracy verification under 493.1236(c). Source: 42 CFR Part 493 Subpart H - Proficiency Testing (eCFR), 42 CFR Part 493 Subpart K - Quality System for Nonwaived Testing (eCFR).

Does SLC cover every specialty?

Yes. SLC consults across all CLIA specialties; it does not perform testing. Source: CMS - Clinical Laboratory Improvement Amendments (CLIA).

Sources

Related pages

Book a free consultation

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.