Short answer: Point-of-care tests reach clinics and pharmacies running under a CLIA Certificate of Waiver only after FDA categorizes them as waived, through a CLIA Waiver by Application or a Dual 510(k) and CLIA waiver. Tests cleared or approved for home (OTC) use are waived automatically but need lay-user labeling, human factors work and lay-user performance data.
Last reviewed: November 21, 2026. Primary sources: FDA, Over-the-Counter (OTC) Medical Devices: Considerations for Device Manufacturers, FDA guidance, Applying Human Factors and Usability Engineering to Medical Devices, FDA, CLIA Waiver by Application, FDA guidance, Recommendations for CLIA Waiver Applications for Manufacturers of IVDs (Feb 2020, PDF).
Lab, point-of-care and home: why the setting drives the pathway
A point-of-care (POC) test runs near the patient, in a clinic, pharmacy or emergency department, often by staff who are not laboratorians. An over-the-counter (OTC) or home test is bought and run by a lay person. Both change the regulatory questions: who can run the test legally under CLIA, and what evidence shows that the intended user can get a correct result (FDA, CLIA Categorizations; FDA, Over-the-Counter (OTC) Medical Devices: Considerations for Device Manufacturers).
| Setting | CLIA status needed | FDA route | Extra evidence |
|---|---|---|---|
| Moderate or high complexity lab | Certificate of Compliance, Accreditation or Registration | 510(k), De Novo or PMA | Standard analytical and clinical data |
| Point of care under a Certificate of Waiver | Test must be categorized as waived | CW after clearance, or Dual 510(k) and CLIA waiver | Risk analysis, flex studies, untrained-operator studies |
| Home use / OTC | Waived automatically once cleared or approved for home use | 510(k) or De Novo with OTC labeling (PMA for class III) | Lay-user studies, human factors, readable labeling |
Getting a professional POC test into waived sites
Professional-use tests are not waived until FDA grants a CLIA Waiver by Application or a Dual Submission. FDA's waiver guidance asks for a test that is simple, with fail-safes and failure alerts, and for accuracy evidence from untrained operators at a minimum of three intended use sites (FDA guidance, Recommendations for CLIA Waiver Applications for Manufacturers of IVDs (Feb 2020, PDF)). Designing for waiver from the start (unit-use cartridges, built-in controls, automatic timing, unambiguous result display) is far easier than retrofitting.
Building a test for clinics, pharmacies or homes? Sound Lab Consultants can map the pathway early.
OTC and home-use tests
FDA's OTC considerations page describes typical OTC candidates: devices usable outside health care settings, labeled so a lay user can self-select and use them correctly without help from a provider, with low potential for foreseeable misuse (FDA, Over-the-Counter (OTC) Medical Devices: Considerations for Device Manufacturers). FDA also keeps a searchable list of authorized OTC home-use IVDs. For IVDs, plan for:
- Labeling under 21 CFR 809.10 that lets a lay user decide the test is right for them, use it correctly without help and act on the result, including when to seek care.
- Human factors and usability engineering, including validation testing with representative users on critical tasks (FDA guidance, Applying Human Factors and Usability Engineering to Medical Devices).
- Lay-user performance studies in realistic conditions: self-collection, reading the result and acting on it.
- Readable result displays or companion apps; app software brings its own documentation and cybersecurity questions.
- FDA says switching a 510(k)-cleared prescription device to OTC labeling likely requires a new premarket submission; a 510(k) can work if lay users fall within the predicate's intended use, otherwise De Novo or PMA may be needed (FDA, Over-the-Counter (OTC) Medical Devices: Considerations for Device Manufacturers).
Design features FDA looks for in near-patient tests
| Feature | Why it matters |
|---|---|
| Few, simple steps | Every manual step is a source of user error in the risk analysis |
| Pre-measured, stable reagents | Lowers the CLIA score and the risk of preparation errors |
| Internal procedural controls | Shows the run worked without separate QC skills |
| Lockouts and error messages | Prevents a result when sample volume, temperature or timing is out of range |
| Clear result display | Reduces interpretation errors, especially near the cutoff |
| Quick reference instructions | Matches how busy clinic staff actually work |
After launch: what POC customers need
- Sites still need the right CLIA certificate and must follow the manufacturer's instructions exactly; see waived testing compliance and the point-of-care testing checklist.
- Moderate complexity POC tests bring CLIA quality control, proficiency testing and personnel rules for the site; some labs use an IQCP, covered on IQCP for point-of-care testing.
- Complaints and adverse events flow into your complaint handling and Medical Device Reporting system.
How Sound Lab Consultants helps
- Setting and pathway strategy for lab, POC and OTC versions of a test
- Waiver-oriented design reviews against FDA's waiver guidance and the CLIA scorecard
- Human factors and lay-user study planning
- Lay-user labeling and quick reference instruction review
- Customer site compliance materials for waived and moderate complexity settings
Talk about your point-of-care or OTC plan with Sound Lab Consultants.
Frequently asked questions
Are home-use tests automatically CLIA waived?
Yes. FDA categorizes tests cleared or approved for home use as waived following clearance or approval. They still need an FDA marketing authorization with OTC labeling first.
How does a point-of-care test become CLIA waived?
A professional-use test becomes waived only if FDA grants a CLIA Waiver by Application after clearance, or clears it through a Dual 510(k) and CLIA Waiver submission. FDA must find the test simple with an insignificant risk of erroneous results.
Do OTC diagnostic tests need human factors studies?
FDA points OTC device makers to its human factors and usability engineering guidance, because lay users may differ from professionals in literacy, vision, dexterity and how they process information. Validation with representative users on critical tasks is the usual way to show safe and effective use.
Can a prescription test be switched to OTC?
FDA says changing a 510(k)-cleared prescription device to OTC labeling likely requires a new premarket submission. A 510(k) may work if lay users fall within the predicate's intended use; if lay-user data raise different questions of safety or effectiveness, De Novo or PMA may be required.
Sources
- FDA, Over-the-Counter (OTC) Medical Devices: Considerations for Device Manufacturers
- FDA guidance, Applying Human Factors and Usability Engineering to Medical Devices
- FDA, CLIA Waiver by Application
- FDA guidance, Recommendations for CLIA Waiver Applications for Manufacturers of IVDs (Feb 2020, PDF)
- FDA, CLIA Categorizations
- 21 CFR 809.10, labeling for IVD products
- FDA, Medical Device Reporting (MDR)
- 42 CFR 493.15, laboratories performing waived tests
Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the U.S. Department of Health and Human Services, any state survey agency, the College of American Pathologists, COLA, The Joint Commission, AABB, ACHC, ASHI, A2LA or any other accrediting organization or Medicare contractor. This page is general regulatory information, not legal, billing or medical advice. Confirm current requirements with FDA, CMS or the agency that oversees your product or laboratory. Only FDA decides clearance, authorization, approval, categorization and CLIA waiver; no consultant can guarantee an outcome. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.