Short answer: An FDA Pre-Submission (Pre-Sub) is a Q-Submission that asks FDA for written feedback, and optionally a meeting, on specific questions before a 510(k), De Novo, CLIA waiver or Dual Submission. Under FDA's May 2025 Q-Sub guidance, written feedback is due within 70 days or 5 days before the meeting. Focused questions with full protocols get the most useful answers.
Last reviewed: November 21, 2026. Primary sources: FDA guidance, The Q-Submission Program (May 2025), FDA, Q-Submission Program guidance (PDF), FDA, CLIA Waiver by Application, 21 CFR 812.2, applicability and IVD exemption.
What the Q-Submission program is
The Q-Submission (Q-Sub) program is how a device sponsor asks FDA for feedback or a meeting outside a marketing submission. FDA's current guidance was finalized on May 29, 2025 and covers interactions tied to IDEs, PMAs, De Novo requests, 510(k)s, CLIA Waiver by Applications and Dual Submissions, among others (FDA guidance, The Q-Submission Program (May 2025)). For IVDs the Pre-Submission (Pre-Sub) is the workhorse: written feedback on specific questions, optionally followed by a meeting.
Q-Sub types and FDA timeframes
| Q-Sub type | What you get | FDA timeframe in the guidance |
|---|---|---|
| Pre-Submission with meeting | Written feedback in advance, then a meeting | Written feedback by day 70 or 5 days before the meeting, whichever is sooner; meeting typically day 70 to 75 |
| Pre-Submission, written feedback only | Written feedback | 70 days |
| Submission Issue Request (SIR) | Discussion of a hold letter or deficiencies | 21 days if within 60 days of the FDA letter, otherwise 70 days, as resources permit |
| Study Risk Determination | FDA letter on whether a study is significant risk, nonsignificant risk or exempt | 90 days |
| Informational Meeting | FDA listens to an overview; no feedback expected | 90 days |
Source: Table 1 of the Q-Sub guidance (PDF). FDA recommends one Q-Sub at a time per device, with supplements for later topics.
When an IVD Pre-Sub pays off
- Predicate choice is arguable, or the intended use goes beyond the predicate's.
- You are choosing between 510(k) and De Novo.
- You plan a Dual 510(k) and CLIA waiver; FDA expects you to signal it in a Pre-Sub (FDA, CLIA Waiver by Application).
- You are designing waiver studies, untrained-operator protocols or flex studies (CLIA Waiver by Application).
- The clinical specimen plan, comparator method or statistics are new for the test type.
- You need to know whether a study is exempt under 21 CFR 812.2(c)(3) or needs an IDE.
Want FDA's view on your predicate or study plan? Sound Lab Consultants can draft the Pre-Sub.
How to write questions FDA can answer
- Lead with a short device description and the exact proposed intended use.
- Keep the number of topics small and tied to your current priority; FDA's guidance says limiting topics lets the review focus.
- Ask closed questions with your proposal attached: 'Does FDA agree that the proposed predicate is appropriate given the differences in Table 2?' works better than 'What predicate should we use?'
- Attach full protocols, not summaries, for any study you want feedback on, including acceptance criteria and the statistical plan.
- State what you will do if FDA disagrees, so feedback can address the alternative.
- Submit through the CDRH Portal and track the review clock.
After a meeting, the submitter drafts the minutes and sends them to FDA within 15 days (Q-Sub guidance). Feedback is not a decision on the later submission, but FDA's guidance explains when it intends to stand by advice it gave.
Pre-Sub mistakes that waste the 70 days
- Asking open questions with no proposal, which invites general answers.
- Sending study summaries instead of full protocols, so FDA cannot comment on sample size, specimens or statistics.
- Changing the intended use between the Pre-Sub and the marketing submission without telling FDA.
- Putting too many unrelated topics in one Q-Sub, or filing several Q-Subs on the same device at once, which FDA's guidance advises against.
- Running the pivotal study before FDA's feedback arrives, then having to repeat it.
- Not recording FDA's answers accurately in the minutes, which weakens your ability to rely on them later.
Typical contents of an IVD Pre-Sub
| Section | What to include |
|---|---|
| Cover letter | Q-Sub type, meeting request or written-feedback-only, preferred dates |
| Device description | Technology, analyte, specimen, controls, instrument and software |
| Proposed intended use | Exact wording, including setting and prescription or OTC use |
| Regulatory history | Prior Q-Subs, EUAs, 513(g) or marketing submissions |
| Planned submission | 510(k), De Novo, Dual, CW or EUA, with proposed predicate or classification |
| Protocols | Analytical, clinical, flex and human factors protocols as relevant |
| Questions | Numbered, specific, with your proposal and rationale |
How Sound Lab Consultants helps
- Pre-Sub strategy and sequencing across the program
- Question drafting with proposals and rationale
- Protocol and statistical plan preparation for FDA review
- Meeting preparation, attendance and minutes drafting
- Study Risk Determination requests
Plan your next FDA interaction with Sound Lab Consultants.
Frequently asked questions
How long does FDA take to answer a Pre-Submission?
FDA's Q-Submission guidance sets written feedback at 70 days, or 5 days before a scheduled meeting if that is sooner. Meetings are typically held around day 70 to 75.
Is a Pre-Submission required?
Usually it is optional, but FDA expects a Pre-Submission before a Dual 510(k) and CLIA Waiver submission and recommends one before De Novo requests and waiver studies.
Who writes the meeting minutes?
The submitter drafts the minutes and sends them to FDA within 15 days of the meeting. FDA may edit them before they are final.
How many questions should a Pre-Sub include?
FDA does not set a fixed number, but its guidance recommends limiting the topics in a single Q-Sub to the current priority and using supplements for later topics.
Sources
- FDA guidance, The Q-Submission Program (May 2025)
- FDA, Q-Submission Program guidance (PDF)
- FDA, CLIA Waiver by Application
- 21 CFR 812.2, applicability and IVD exemption
- FDA, De Novo Classification Request
- FDA, CDRH Portal for premarket submissions
Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the U.S. Department of Health and Human Services, any state survey agency, the College of American Pathologists, COLA, The Joint Commission, AABB, ACHC, ASHI, A2LA or any other accrediting organization or Medicare contractor. This page is general regulatory information, not legal, billing or medical advice. Confirm current requirements with FDA, CMS or the agency that oversees your product or laboratory. Only FDA decides clearance, authorization, approval, categorization and CLIA waiver; no consultant can guarantee an outcome. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.