510(k) Consulting for In Vitro Diagnostic Tests

Short answer: A 510(k) for an IVD is a premarket notification showing FDA that a new test is substantially equivalent to a legally marketed predicate test with the same intended use. It relies on analytical and clinical performance data, labeling under 21 CFR 809.10 and an eSTAR file. FDA usually decides within 90 review days, and the FY 2027 user fee is $28,653.

Last reviewed: November 21, 2026. Primary sources: FDA, Premarket Notification 510(k), FDA guidance, The 510(k) Program: Evaluating Substantial Equivalence, FDA, Content of a 510(k), 21 CFR 807.87, information required in a premarket notification.

Book a free consultation

What a 510(k) is for an IVD

A 510(k) is a premarket notification that shows FDA your device is substantially equivalent to a legally marketed predicate. You may not market the device until FDA issues an order finding it substantially equivalent (FDA, Premarket Notification 510(k); 21 CFR 807.100). For IVDs, the predicate is usually a cleared test for the same analyte, specimen type and intended use, and the comparison rests mainly on analytical and clinical performance data rather than bench engineering tests.

Substantial equivalence means the new test has the same intended use as the predicate and either the same technological characteristics, or different ones that do not raise different questions of safety and effectiveness and are shown to be as safe and effective (FDA guidance, The 510(k) Program: Evaluating Substantial Equivalence).

When an IVD needs a 510(k)

What goes into an IVD 510(k)

FDA requires electronic submission through eSTAR for 510(k)s, unless exempted, since October 1, 2023 (FDA, Premarket Notification 510(k); FDA, eSTAR Program). The regulation lists the required elements (21 CFR 807.87), and eSTAR organizes them. For an IVD, plan for:

SectionWhat FDA looks for in an IVD fileSource
Device description and intended useAnalyte, method, specimen, population, setting, prescription or OTC use, controls and calibrators807.87
Predicate comparisonSide-by-side table of intended use and technology with the predicate and an explanation of each difference510(k) Program guidance
Analytical performancePrecision and reproducibility, linearity or reportable range, limit of detection, analytical specificity, interference, cross-reactivity, carryover, specimen and reagent stabilityFDA Content of a 510(k)
Method comparison or clinical performanceAgreement with the predicate or a reference method on clinical specimens, with a pre-specified statistical planFDA GCP for IVD data
LabelingPackage insert with intended use, procedure, limitations, expected values and performance; labels per 809.1021 CFR 809.10
Software and cybersecurityWhere the instrument or app uses softwareFDA Content of a 510(k)
510(k) summary or statement and truthful-and-accurate statementPublic summary of the basis for equivalence21 CFR 807.92

Need a predicate strategy or study plan for your 510(k)? Sound Lab Consultants can review it with you.

Book a free consultation

Review timeline and FY 2027 user fee

FDA says the substantial equivalence decision is usually made within 90 days of FDA review time (FDA, Premarket Notification 510(k)). Questions are handled through interactive review or an Additional Information letter that puts the file on hold until you answer. The FY 2027 510(k) user fee is $28,653, or $7,163 for a qualified small business, and applies to Traditional, Special and Abbreviated 510(k)s (FDA, MDUFA User Fees (FY 2027)). These are FDA fees, not Sound Lab Consultants fees.

After clearance, FDA assigns the test's CLIA category. Most new professional-use tests land in moderate or high complexity; waived status for point-of-care use requires a separate CLIA Waiver by Application or a Dual Submission filed in place of the stand-alone 510(k) (FDA, CLIA Categorizations).

Where IVD 510(k)s commonly run into trouble

  • An intended use that is broader than the predicate's, or a new specimen type, without data to support it.
  • Specimens that do not reflect the intended population, too few positives near the cutoff, or contrived samples used where clinical samples were expected.
  • Statistical analysis decided after unblinding, or acceptance criteria that were never written down.
  • Stability claims in the label that the real-time data do not yet cover.
  • Design control records that cannot show where the performance specifications came from.
  • Skipping a Pre-Submission when the predicate choice or study design is debatable.

How a 510(k) project usually runs

  1. Confirm product code, regulation number and the best predicate; record the reasoning.
  2. Write the analytical and clinical protocols with acceptance criteria tied to the predicate's labeled performance.
  3. Hold a Pre-Submission if the predicate, specimen set or statistics are open questions.
  4. Run studies under design controls; lock data and analyze per plan.
  5. Draft labeling and the eSTAR, check every element, pay the user fee and submit through the CDRH Portal.
  6. Answer interactive questions and any Additional Information letter completely and on time.
  7. After clearance: registration and listing, CLIA categorization check, complaint handling and MDR procedures.

How Sound Lab Consultants helps

  • Predicate and product code research with a written rationale
  • Analytical and method comparison protocols and statistical analysis plans
  • eSTAR drafting, labeling and 510(k) summary preparation
  • Pre-Submission questions on predicate choice and study design
  • Responses to interactive review and Additional Information letters
  • Change assessments for modified cleared tests, and links to CLIA waiver planning

Bring your intended use and draft data; we will help you plan the 510(k).

Book a free consultation

Frequently asked questions

What is substantial equivalence for a diagnostic test?

It means the new test has the same intended use as a legally marketed predicate and either the same technological characteristics, or different characteristics that do not raise different questions of safety and effectiveness and are supported by data showing it performs as well.

Is eSTAR required for an IVD 510(k)?

Yes. Since October 1, 2023, FDA requires 510(k) submissions to be sent as eSTAR electronic submissions unless an exemption applies.

How long does FDA take to clear a 510(k)?

FDA states that substantial equivalence decisions are usually made within 90 days of FDA review time. Time spent on hold waiting for answers to an Additional Information request is not counted, so calendar time is longer.

What is the FDA 510(k) user fee for FY 2027?

FDA lists $28,653 as the standard FY 2027 510(k) fee and $7,163 for a qualified small business. Small business status needs an approved request before the fee is due.

Does a cleared test become CLIA waived automatically?

Only tests cleared or approved for home use are categorized as waived automatically. Other tests get a moderate or high complexity category, and waiver requires a CLIA Waiver by Application or a Dual 510(k) and CLIA Waiver submission.

Sources

Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the U.S. Department of Health and Human Services, any state survey agency, the College of American Pathologists, COLA, The Joint Commission, AABB, ACHC, ASHI, A2LA or any other accrediting organization or Medicare contractor. This page is general regulatory information, not legal, billing or medical advice. Confirm current requirements with FDA, CMS or the agency that oversees your product or laboratory. Only FDA decides clearance, authorization, approval, categorization and CLIA waiver; no consultant can guarantee an outcome. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.