De Novo Classification for Novel Diagnostic Tests

Short answer: De Novo is the FDA pathway for a novel diagnostic test that has no legally marketed predicate but whose risks can be managed by general and special controls, placing it in class I or II. The request, filed in eSTAR under 21 CFR 860 Subpart D, lists risks, mitigations and proposed special controls. FDA's decision goal is 150 review days.

Last reviewed: November 21, 2026. Primary sources: FDA, De Novo Classification Request, eCFR, 21 CFR Part 860 Subpart D, De Novo classification, FDA, MDUFA User Fees (FY 2027), FDA, Small Business Determination (SBD) Program.

Book a free consultation

What De Novo means for a diagnostic

De Novo is the pathway for a new type of device that has no legally marketed predicate but whose risks can be controlled by general controls, or by general and special controls, so that it can be placed in class I or II instead of class III (FDA, De Novo Classification Request; 21 CFR 860 Subpart D). For IVDs it is common for first-of-a-kind analytes, new biomarkers, new clinical claims and novel test formats. A granted De Novo creates a new classification regulation, and the device can then serve as a predicate for later 510(k)s.

Two ways to file

OptionWhen it appliesSource
After a 510(k) NSEYou filed a 510(k) and FDA found the device not substantially equivalent because there is no predicate, a new intended use or different technology raising different questions21 CFR 860.200
Direct De NovoYou determine there is no legally marketed device on which to base substantial equivalenceFDA De Novo

FDA recommends a Pre-Submission before a De Novo so the review division can comment on the risk analysis, the proposed special controls and the clinical plan (FDA, De Novo Classification Request).

What a De Novo request contains

Required content is set out in 21 CFR 860.220 and collected by eSTAR, which became mandatory for De Novo requests on October 1, 2025 (FDA, De Novo Classification Request; eCFR, 21 CFR Part 860 Subpart D, De Novo classification). For an IVD, the core is:

  • Administrative information and full regulatory history, including any prior 510(k), Pre-Submission, 513(g) or EUA for the device.
  • Device description, intended use, indications and prescription or OTC designation.
  • A recommended classification and a search showing why no predicate exists.
  • A list of probable risks to health for the device type, with the mitigation for each one.
  • Proposed special controls, written so they can apply to later devices of the same type.
  • Analytical and clinical performance data that support the claimed performance and the benefit-risk balance.
  • Labeling under 21 CFR 809.10.

Working on a first-of-a-kind test? Sound Lab Consultants can help you frame the risks and special controls.

Book a free consultation

Review steps, timeline and FY 2027 fee

StepWhat happensSource
Technical screeningWithin about 15 calendar days of receipt; incomplete eSTARs are placed on holdFDA De Novo
Substantive reviewClassification review and evaluation of data; interactive questions or an Additional Information letterFDA De Novo
Additional Information holdComplete response due within 180 calendar days, with no extensions; otherwise withdrawnFDA De Novo
DecisionGoal of 150 review days; grant creates a new classification regulation, decline leaves the device in class IIIFDA De Novo

The FY 2027 De Novo user fee is $191,020, or $47,755 for a qualified small business (FDA, MDUFA User Fees (FY 2027)). FDA's FDA, Breakthrough Devices Program may also apply to some novel diagnostics that offer more effective diagnosis of life-threatening or irreversibly debilitating conditions.

Writing special controls that hold up

  • Tie every special control to a named risk, such as false negatives in a specific population or cross-reactivity with a related organism.
  • Use performance language a future 510(k) applicant can test against: study types, specimen types and the information the labeling must disclose.
  • Look at decision summaries for nearby De Novo IVDs to see how FDA has phrased controls for similar risks.
  • Keep claims and studies aligned: an indication you cannot support with data invites a decline or a narrower grant.

CLIA categorization after a grant

A granted De Novo receives a CLIA category through a concurrent CLIA Record (FDA, CLIA Categorizations). If the test is meant for point-of-care use, FDA has said it intends to accept Dual De Novo and CLIA Waiver submissions in some EUA transition situations, modeled on the Dual 510(k) pathway (FDA, CLIA Waiver by Application). Otherwise a CLIA Waiver by Application follows the grant.

How Sound Lab Consultants helps

  • Predicate searches and a written De Novo versus 510(k) rationale
  • Risk-to-mitigation tables and draft special controls
  • Pre-Submission packages focused on the clinical plan and benefit-risk
  • eSTAR De Novo drafting, labeling and response management
  • Breakthrough designation request assessment where criteria may be met

Discuss whether De Novo or 510(k) fits your test.

Book a free consultation

Frequently asked questions

When is De Novo used instead of a 510(k)?

De Novo is used when no legally marketed predicate exists for the device type, but general controls or general and special controls can provide reasonable assurance of safety and effectiveness. If a suitable predicate exists, a 510(k) is the usual route.

How long does FDA take to decide a De Novo?

FDA's goal is a decision within 150 review days. Days on hold for an Additional Information response are excluded, and the response must arrive within 180 calendar days.

What is the FDA De Novo fee for FY 2027?

FDA lists the FY 2027 De Novo classification request fee as $191,020, or $47,755 for a qualified small business.

Is eSTAR required for De Novo requests?

Yes. Starting October 1, 2025, FDA requires De Novo requests to be submitted as eSTAR electronic submissions unless an exemption applies.

Can a De Novo device be a predicate later?

Yes. Once FDA grants a De Novo and classifies the device into class I or II, that device can be used as a predicate for future 510(k) submissions where appropriate.

Sources

Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or acting for CMS, CDC, FDA, the U.S. Department of Health and Human Services, any state survey agency, the College of American Pathologists, COLA, The Joint Commission, AABB, ACHC, ASHI, A2LA or any other accrediting organization or Medicare contractor. This page is general regulatory information, not legal, billing or medical advice. Confirm current requirements with FDA, CMS or the agency that oversees your product or laboratory. Only FDA decides clearance, authorization, approval, categorization and CLIA waiver; no consultant can guarantee an outcome. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.