Joint Commission Laboratory Competency Assessment
Joint Commission laboratory competency assessment is the formal, documented check that each person can apply their knowledge, skills and training to the tests they perform. For non-waived testing it follows CLIA: six elements, twice in the first year, then yearly, and again before reporting results on a new method or instrument. Hospital waived testing adds orientation and annual checks under NPG 10.
Last reviewed: November 3, 2026. Main sources: CMS, CLIA Assessing Personnel Competency (revised May 2025, PDF), 42 CFR 493.1413 and 493.1451, CMS State Operations Manual Appendix C, The Joint Commission Laboratory Survey Activity Guide 2025 (PDF) and Joint Commission National Performance Goal #10: Waived Testing.
What competency assessment means
In CMS's words, competency is whether a person can put their skills, knowledge, training and experience to correct use in the lab work they are assigned (CMS brochure). A competency assessment is the formal, documented way a lab checks that ability for each person and each test they perform. CLIA requires it for everyone who performs moderate or high complexity (non-waived) testing. The lab must also have written policies for assessing employee and, if applicable, consultant competency (42 CFR 493.1235).
Put simply, a competency assessment answers one question: after training, does this person perform and report this test correctly, following our procedure? A signed checklist alone doesn't answer it. The evidence does: observed testing, reviewed records, sample results and documented problem solving.
Key rules at a glance
Training is not competency
Training teaches someone your procedure. Competency assessment proves, later and with evidence, that they now run and report the test correctly on their own. CMS treats the two as separate requirements, and The Joint Commission goes a step further by expecting separate records for initial training and initial competency (CMS brochure; MLO).
A checklist records evidence; it isn't the evidence
A form with boxes is fine as a place to log what was assessed. What a surveyor looks for behind each box is the proof: the dated observation, the QC and maintenance logs that were reviewed, the blind or PT sample result, and the problem-solving case. A checklist signed without those, or one that skips any of the six elements, won't meet the CLIA rule.
The assessor depends on test complexity
Moderate complexity: the technical consultant, or a person who meets technical consultant qualifications. High complexity: the technical supervisor, or a general supervisor the technical supervisor has delegated in writing. Provider-performed microscopy: the laboratory director. Waived testing in Joint Commission hospitals: a supervisor or qualified designee, under hospital policy (493.1413; 493.1451; 493.1463).
Surveyors look at people, paper and practice
Expect a Human Resources and Competence Assessment session, file pulls for staff the surveyor met on tracers, job descriptions checked against education and credential minimums, and a 24-month look-back on training and competency records (SAG 2025). Details are in what surveyors check.
How The Joint Commission lines up with CLIA
The Joint Commission's laboratory program is approved by CMS under CLIA, and to apply a lab must hold a non-waived CLIA certificate (TJC Laboratory Services). Its competency rules for non-waived testing mirror CLIA. In April 2024, The Joint Commission listed HR.01.06.01, EP 18 among the five laboratory requirements most often found non-compliant in 2023. That element of performance lists the same six components as CLIA (Joint Commission Online, Apr 3, 2024).
Where The Joint Commission adds to CLIA:
- Separate training and competency records. A Joint Commission laboratory field director says initial training and initial competency must be documented separately, and that other accreditors and CMS don't require this (MLO, Dec 2025).
- Waived testing competency in hospitals and critical access hospitals, which CLIA doesn't require (see waived testing).
- A dedicated survey session on HR and competence, plus file checks tied to tracers (SAG 2025).
Training vs competency vs performance evaluation
| Training | Competency assessment | Performance evaluation | |
|---|---|---|---|
| Question it answers | Was the person taught our method? | Does the person perform and report the test correctly, following our procedure? | How well does the person do the job overall (behaviors, attributes)? |
| When | Before the person starts testing; again for new methods | After training, then on the CLIA schedule | On the employer's HR cycle |
| Who signs | Trainer | Qualified assessor (TC, TS or delegated GS) | Manager |
| Meets CLIA competency rule? | No | Yes, if all six elements are documented | No |
CMS is explicit that training records and personnel evaluations are different things and can't substitute for a CLIA competency assessment (CMS brochure). CMS's 2013 guidance made the same point that competency assessment is not a performance evaluation (ADLM CLN, June 2013). For Joint Commission labs, keep a dated training checklist signed by the trainer and a separate initial competency record covering all six elements, completed before the person reports patient results on their own.
When to assess: the competency timeline
| Point in time | What is required | Source |
|---|---|---|
| Hire / orientation | Train on each test system and document it. Complete the initial competency before independent patient testing (a Joint Commission expectation, kept separate from training). | CMS brochure; MLO |
| First year of patient testing | At least two assessments (semiannual). Many labs schedule them at about 6 and 12 months. | 493.1413(b)(9); 493.1451(b)(9) |
| Every year after | At least annually, with all six elements documented for each person each year. | Same; CMS brochure |
| New method or instrument | Reassess on the new method or instrument before the person reports patient results with it. | 493.1413(b)(9); 493.1451(b)(9) |
| Problems found | Policies must identify remedial training or continuing education needs whenever necessary. | 493.1407(e)(12); 493.1445(e)(13) |
| Supervisors and consultants | Assessed on their regulatory duties at a frequency the lab sets, plus the six elements if they test. | Appendix C, D5209 |
| Waived testing (TJC hospitals/CAHs) | Training documented for each test; competency at orientation and at least annually, two of four methods per person per test. | NPG.10.02.01 |
"Semiannually" means at least twice in the first 12 months. The year-one clock starts when the person first tests patient specimens in your lab, so an experienced new hire still needs two assessments in their first year with you.
New non-waived testing personnel
Document orientation and training on each test system first. Then complete and sign an initial competency record covering all six elements before the person reports patient results alone. Then make sure two assessments are documented before the 12-month mark from their first patient test.
Existing staff
At least once a year, with all six elements documented for each test or test system the person performs. The year is a window, not a single day: gather evidence as routine QC review, maintenance and troubleshooting happen, then have the assessor review and sign.
New method, new instrument or a change in technique
CLIA ties this trigger to patient reporting, not to the calendar: the person is reevaluated on the new method or instrument before they report patient results with it. Build that sign-off into your go-live checklist so the analyzer can't go live with untrained staff.
Waived testing
CLIA has no competency rule for staff who only perform waived tests. Joint Commission hospitals and critical access hospitals must still assess waived testing competency at orientation and at least annually under NPG 10 (details below).
The six CLIA competency elements, with evidence examples
| # | Element (42 CFR 493.1413(b)(8) / 493.1451(b)(8)) | CMS D-tags (TC / TS) | Evidence that works |
|---|---|---|---|
| 1 | Direct observation of routine patient test performance, including patient preparation if applicable, and specimen handling, processing and testing | D6047 / D6121 | Dated observation checklist for a real patient run, signed by the assessor |
| 2 | Monitoring the recording and reporting of test results | D6048 / D6122 | Review of results the person reported, including critical value calls and corrected reports |
| 3 | Review of intermediate results or worksheets, QC records, PT results and preventive maintenance records | D6049 / D6123 | Initialed QC and maintenance logs the assessor reviewed, linked to the person |
| 4 | Direct observation of instrument maintenance and function checks | D6050 / D6124 | Observed daily or weekly maintenance and function checks (not required for PPM) |
| 5 | Assessment of test performance using previously analyzed specimens, internal blind samples or external PT samples | D6051 / D6125 | Blind or repeat-sample results compared with expected values, or the person's PT results |
| 6 | Assessment of problem-solving skills | D6052 / D6126 | Written case questions, or a documented real event such as a QC failure or delta-check investigation |
Timing is cited at D6053-D6055 (moderate) and D6127-D6128 (high complexity) (CMS Appendix C). The Joint Commission's HR.01.06.01 EP 18 wording is a little broader in places. It adds specimen collection to element 1, calibration to element 4, and "as appropriate to the job" to element 6 (source).
Most of this evidence already exists in daily work. A Joint Commission field director told ADLM that labs often build competency programs from scratch instead of capturing the QC reviews, maintenance and troubleshooting staff already do. Joint Commission staff also stressed that the year is a window for collecting evidence, not a single test day (ADLM CLN). Two practical habits help: give each person a folder (paper or electronic) where they drop evidence as they complete an element, and remember that pathologists and doctoral-level staff who test are assessed too (ADLM CLN). The most common miss is element 4: it calls for direct observation of maintenance and function checks, so a reviewed maintenance log on its own covers element 3, not element 4. For a printable layout, use the template below, our competency assessment form and six elements guide.
Who must be assessed
- Testing personnel (TP): all six elements, for every test they perform (CMS brochure).
- Technical consultant, technical supervisor, general supervisor, clinical consultant: a documented assessment based on their Subpart M duties, at a frequency the lab sets. If they also test patient specimens, they need the six elements too (Appendix C, D5209).
- Laboratory director: if the director tests, they are assessed. If the director is the only person testing and reporting, they must set and document a minimum proficiency level, for example through PT samples or outside review of their work.
- Provider-performed microscopy (PPM): five of the six elements; observing instrument maintenance doesn't apply. In a PPM-certificate lab, the director assesses competency, on the same schedule (493.1359; Appendix C D5988-D5989).
- Contracted, per diem and traveling staff: the Survey Activity Guide lists contracted staff competency as an HR session topic.
- Non-testing staff (phlebotomists who only draw, accessioners, specimen processors): not required by CLIA, but CMS calls it good practice, and the director's policies must cover pre- and post-analytic staff. A phlebotomist who performs bleeding times is doing moderate complexity testing and needs a full assessment.
Who can assess competency, and who can't
| Testing performed | Who may assess | Rule |
|---|---|---|
| Moderate complexity | Technical consultant, or anyone who meets TC qualifications and is delegated in writing | 493.1413(b)(8); TC qualifications 493.1411 |
| High complexity | Technical supervisor, or a general supervisor delegated in writing. The TS stays responsible. | 493.1451(b)(8)-(9); 493.1463(b)(4); GS qualifications 493.1461 |
| PPM certificate | Laboratory director; may delegate individual procedures in writing to other qualified PPM testing personnel | 493.1359; CMS brochure |
| Waived only (CLIA) | No CLIA requirement; under TJC NPG 10, a "supervisor or qualified designee" observes routine work | CMS brochure; NPG.10.02.01 EP 2 |
The laboratory director is ultimately responsible for making sure all assessments get done (CMS brochure). For Certificate of Accreditation labs, CMS tells directors to check delegation questions with their accrediting organization. Qualification rules changed on December 28, 2024, with grandfathering for some people already serving (for example 493.1461(c)(4) for general supervisors). Check current eCFR text, not older summaries. See our technical consultant, technical supervisor and general supervisor pages.
Per test, per platform: how granular to go
CMS's current brochure says the six procedures apply to every test a person performs, even when several tests run on one platform, and that the assessment must include the specific test procedures the person performs (CMS brochure). CMS's 2013 guidance, as reported by ADLM CLN, let labs assess tests on the same test system (for example, one chemistry analyzer) together, unless a test had unique aspects, problems or procedures. The current brochure still singles those tests out, with ammonia received on ice as an example. Practical approach:
- Document each platform-level assessment so it names every test it covers.
- Assess tests with special handling, manual steps, calculations or unique QC separately.
- Assess manual methods (slide reviews, manual differentials, urine sediment) separately. Appendix C asks surveyors how the lab checks consistency in slide review.
- Keep a test-system matrix per person so a surveyor can match any tracer test to a dated assessment.
Waived testing: CLIA exemption vs Joint Commission requirements
What counts as a waived test
CLIA describes waived tests as simple procedures with an insignificant risk of an erroneous result. The Joint Commission's NPG page gives blood glucose, fecal occult blood and rapid strep as common examples, and notes that simple doesn't mean error proof: a wrong waived result can still lead to misdiagnosis, delayed or wrong treatment, or a medication error (TJC NPG #10).
CLIA: no formal competency rule for waived-only staff
CLIA: labs that perform only waived tests must follow the manufacturer's instructions (42 CFR 493.15(e)). CLIA has no competency assessment requirement for staff who only do waived testing, though CMS recommends it as good practice and says staff must be properly trained (CMS brochure). The FDA keeps the list of CLIA-waived tests.
The Joint Commission: National Performance Goal 10
The Joint Commission, hospitals and critical access hospitals: since January 1, 2026, waived testing sits in the National Performance Goals chapter, which replaced the National Patient Safety Goals chapter for those two programs (TJC NPGs). Goal 10 says the hospital performs waived testing safely and consistently (NPG chapter, Hospital, PDF):
- NPG.10.01.01: written waived testing policies, set by the person named on the CLIA certificate or a qualified designee, consistent with the manufacturer's instructions and covering QC, reagents, specimen handling and result reporting.
- NPG.10.02.01 EP 1: staff are trained for each waived test they are authorized to perform, including instrument use and maintenance, and the training is documented.
- NPG.10.02.01 EP 2: competency is assessed at defined intervals, at least at orientation and annually, using at least two of these methods per person per test: a blind specimen, periodic observation by a supervisor or qualified designee, monitoring the user's QC performance, or a written test specific to that test.
- Wording note: the public NPG web page says competency is assessed with "more than one method"; the NPG chapter PDF sets the floor at two of the four listed methods. Plan for two.
- Licensed practitioners who run non-instrument waived tests in their specialty may be covered through credentialing and privileging instead of annual competency. PPM procedures are not waived tests.
Related: waived test quality control.
Joint Commission standard numbers you can verify publicly
| Standard / EP | Program | Topic | Public source |
|---|---|---|---|
| HR.01.06.01, EP 18 | Laboratory and Point-of-Care Testing | Six components of a staff member's competency assessment | JC Online, Apr 3, 2024 (2023 data) |
| NPG.10.01.01, EPs 1-2 | Hospital, CAH (eff. Jan 1, 2026) | Waived testing policies and procedures | NPG chapter PDF |
| NPG.10.02.01, EPs 1-2 | Hospital, CAH (eff. Jan 1, 2026) | Waived testing training and competency | NPG chapter PDF |
| EC.02.04.03, EP 7 | Laboratory | Instrument maintenance; HEADS UP lists missing annual maintenance competencies as a contributing factor | HEADS UP PDF |
| QSA.02.08.01, EP 2 | Laboratory | Correlation testing every six months; HEADS UP lists annual competence that left out non-waived testing as a contributing factor | HEADS UP PDF |
| QSA.05.18.01, EP 7 | Laboratory | Transfusion monitoring; HEADS UP asks for annual transfusion competencies | HEADS UP PDF |
EP numbers can change between manual editions. Confirm the current wording in your E-dition before quoting a number in a policy or a plan of correction.
What Joint Commission surveyors check
The 2025 Laboratory Survey Activity Guide schedules a Human Resources and Competence Assessment session of one to two hours, usually after most tracer activity. Bring someone with authority to open personnel and training files. In that session, the surveyor will:
- Learn how the lab meets the CLIA-required competency assessment for testing personnel
- Review orientation, education and training for technical and non-technical staff met during tracers
- Pick specific staff from the tracers and review their files
- Discuss staffing adequacy, performance improvement tied to competency, ongoing education and the competency process for contracted staff
Have ready on day one (document list, 24-month look-back):
- A list of all testing personnel with qualifications, hire date, and training and competency records for the past 24 months
- Proof of highest education for testing personnel
- Licenses or certifications where state law or your policy requires them
- The laboratory director's credential file and contract
- Personnel files with job descriptions, education, licensure and performance evaluations
A Joint Commission field director adds that in small labs (five or six staff) surveyors will likely review almost every file. They also check that job descriptions match minimum education, experience and credential requirements, and they ask you to show and explain your process instead of interpreting your paperwork for you (MLO). HEADS UP reports for lab equipment maintenance and blood transfusion also tell surveyors to confirm that annual competencies for those tasks are on file (HEADS UP: equipment, HEADS UP: transfusion).
A third HEADS UP report, on correlation testing (QSA.02.08.01 EP 2), found moderate-to-high-risk correlation findings in 96 of 873 full surveys (11%) in early 2019. Among the contributing factors it lists annual competence assessments that didn't include non-waived testing, and its self-check asks whether each person had an annual assessment for every test they perform (HEADS UP: correlation testing). Multi-site systems should also note that the Joint Commission's system survey option looks for standardized training and competency policies and consistent job descriptions across sites (TJC Laboratory Services).
How long to keep competency records
The 24 months surveyors ask for comes from the Survey Activity Guide's document list, and it lines up with CLIA. Under 42 CFR 493.1105, most lab records must be kept at least 2 years, including QC and patient test records, PT records, quality system assessment records and test reports. Some records must be kept longer, so 24 months is a minimum look-back, not a cap:
- Pathology test reports: at least 10 years
- Histopathology slides: at least 10 years; cytology slides: at least 5 years
- Test procedures: at least 2 years after the procedure is discontinued
- Performance specifications: as long as the test system is in use, and no less than 2 years
493.1105 doesn't list personnel or competency files by name. Keep each person's training and competency records for at least two years, longer where your state, accreditor or policy says so.
Accuracy notes on common competency claims
Search summaries tend to compress these rules. Here is how each common phrasing lines up with the official text:
| Common phrasing | What the official text says |
|---|---|
| "Every 6 months in the first year" | "At least semiannually during the first year the individual tests patient specimens." Two assessments minimum, counted from the first patient test in your lab (493.1413(b)(9)). |
| "Competency at orientation" | CLIA requires training before testing and the two first-year assessments. The Joint Commission expects an initial competency record, separate from training, before independent testing. For waived testing, NPG 10 does say "at orientation." |
| "Immediately reassess after a new instrument" | The rule is "prior to reporting patient test results" on the new method or instrumentation. It's tied to patient reporting, not a clock. |
| "Surveyors review 24 months of records" | Accurate for the Survey Activity Guide request. It matches CLIA's 2-year minimum retention, but some records must be kept longer (493.1105). |
| "A supervisor must assess moderate complexity staff" | For moderate complexity the assessor is the technical consultant or someone who meets technical consultant qualifications. Supervisors (TS, or GS by delegation) assess high complexity staff. |
| "Competency every two years" | Not for non-waived lab testing. CLIA requires annual assessment after the first year. |
| "NPG 10 applies to every Joint Commission lab" | The NPG chapter applies to the Hospital and Critical Access Hospital programs. Labs under other programs follow the waived testing standards in their own manual. |
| "A competency checklist is enough" | Only when it records evidence for all six elements per test, signed by a qualified assessor. |
Why proficiency testing alone isn't enough
PT is a strong piece of evidence, but it covers only part of the picture. CMS allows PT results to feed into a competency assessment, but says PT alone falls short of the six procedures and of the CLIA requirement (CMS brochure). PT doesn't show direct observation, result reporting, maintenance or problem solving. It also usually reaches only some staff each event. Use PT for element 5 and PT review for element 3, then cover the other four elements another way.
Common findings and how CMS cites them
- Not all six elements documented, or not for every test system. In 2012, The Joint Commission cited 39% of labs for competency non-compliance, most often for missing elements, missed frequency or unqualified assessors (ADLM CLN). HR.01.06.01 EP 18 was still among the top five lab findings in 2023 (JC Online).
- Only one assessment in the first year.
- Assessor not qualified, or no written delegation.
- Training and initial competency on one combined form (a Joint Commission-specific finding).
- No reassessment after a new analyzer or method went live.
- Contracted, per diem or point-of-care staff missing from the program.
- Supervisors and consultants never assessed on their regulatory duties.
On CMS and state surveys, these are cited at D5209 (competency policies, 493.1235), D6030 / D6103 (director responsibilities), D6046-D6055 (technical consultant, moderate complexity) or D6120-D6128 (technical supervisor, high complexity) (Appendix C). If you received a citation, see failed survey support.
Build a Joint Commission-ready competency program in 10 steps
- Write the policy required by 493.1235: scope, roles, the six elements, timing, assessors, remediation and record retention.
- Build the roster from your CMS-209, adding every person who tests, including contractors, per diem staff and point-of-care staff.
- Map each person to test systems, and flag tests with unique steps that need their own assessment.
- Name the assessors and delegate in writing to people who meet TC, TS or GS qualifications. Keep the delegation letters on file.
- Split the forms: a training checklist signed by the trainer, and a separate competency record with all six elements.
- Schedule the two first-year assessments and the annual cycle, plus triggers for new methods or instruments.
- Collect evidence all year from routine QC review, maintenance logs, PT and real troubleshooting, instead of one competency day.
- Remediate and reassess when someone falls short, and document the retraining.
- Cover waived testing with documented training and at least two methods per person per test, at orientation and annually.
- Audit a sample of files each quarter against the Survey Activity Guide document list, keeping at least 24 months on hand.
Survey file checklist for competency
- Every name on the CMS-209 and testing roster has a current, signed competency record for each test system
- New hires show training and initial competency on separate forms, completed before independent testing
- Two assessments in the first year; annual ones after that; reassessment after method or instrument changes
- Written delegations for every assessor, with proof the assessor meets the qualifications
- Competency for TC, TS, GS and CC duties
- Contracted, per diem and point-of-care staff included
- Waived testing training plus two-method competency documented per test
- 24 months of records retrievable quickly, with someone who can open the files
- Job descriptions that match the education and credential minimums
Related guides: Joint Commission laboratory accreditation requirements, document list, tracer methodology and survey preparation.
Competency assessment template (copy-ready)
Free to copy into your own document system. Adjust it to your test menu and policy. It is a starting layout, not an official CMS or Joint Commission form. Use one record per person, per test or test system, per assessment.
Part A: Header
| Employee name / ID | Role (TP, TC, TS, GS, CC, LD) | ||
|---|---|---|---|
| Test or test system | Complexity (moderate / high / PPM / waived) | ||
| Tests covered by this record | |||
| Assessment type | Initial / first-year #2 / annual / new method or instrument / remedial | ||
| Date of first patient testing in this lab | Assessment window (from - to) | ||
Part B: Six-element record (non-waived testing)
| # | Element | How assessed | Evidence reference (log, run, sample ID, case) | Date | Met / Not met | Assessor initials |
|---|---|---|---|---|---|---|
| 1 | Direct observation of routine patient testing, including patient prep and specimen handling, processing and testing | Observed live run | ||||
| 2 | Monitoring recording and reporting of results | Reviewed reported results, critical calls, corrections | ||||
| 3 | Review of worksheets or intermediate results, QC, PT and preventive maintenance records | Record review | ||||
| 4 | Direct observation of instrument maintenance and function checks (n/a for PPM) | Observed maintenance | ||||
| 5 | Previously analyzed specimens, internal blind samples or external PT samples | Sample results vs expected | ||||
| 6 | Problem-solving skills | Written case or documented real event |
Part C: Waived testing record (NPG 10 hospitals and CAHs)
| Waived test | Training documented (date) | Method 1 used | Method 2 used | Date | Met / Not met | Supervisor or designee |
|---|---|---|---|---|---|---|
| Blind specimen / observation / QC monitoring / written test | Blind specimen / observation / QC monitoring / written test |
Pick at least two different methods per person per test. Repeat at orientation and at least annually.
Part D: Sign-off and remediation
| Overall result | Competent / Not yet competent |
|---|---|
| Remediation plan (if not met) | Retraining topic, trainer, date, reassessment date |
| Assessor name and qualification | TC / TS / delegated GS / LD (PPM); written delegation on file: yes / no |
| Assessor signature and date | |
| Employee signature and date | |
| Laboratory director review (per policy) |
Part E: Roster tracker (one row per person)
| Name | Role | First patient test date | First-year #1 | First-year #2 | Annual due | Test systems covered | Waived tests | Assessor |
|---|---|---|---|---|---|---|---|---|
Keep the training checklist on its own form, signed by the trainer, and file it next to this record rather than merging the two. For the full survey document set, see the Joint Commission laboratory document list.
How Sound Lab Consultants helps
Sound Lab Consultants (SLC) works with clinical labs remotely before Joint Commission, CAP, COLA and state CLIA surveys. For competency, typical work includes:
- Policy rewrites
- Test-system matrices
- Separate training and competency forms
- Assessor qualification and delegation reviews
- Waived testing competency programs
- Mock HR file reviews against the Survey Activity Guide
- Plans of correction after a competency citation
SLC supports all CLIA specialties and subspecialties. See our CLIA consultant, clinical laboratory consulting and CLIA mock inspection pages.
Frequently asked questions
What is competency assessment in a Joint Commission accredited laboratory?
It is a documented, formal check that each staff member can apply their skills, knowledge, training and experience to the tests they are assigned. For non-waived testing, The Joint Commission's laboratory standard (HR.01.06.01, EP 18 in the version The Joint Commission published in April 2024) lists the same six elements CLIA requires in 42 CFR 493.1413(b)(8) and 493.1451(b)(8).
How often is laboratory competency assessed?
Under CLIA, each person who performs moderate or high complexity testing is assessed at least semiannually (twice) during the first year they test patient specimens, then at least annually. If the test method or instrument changes, the person must be reassessed on the new method before reporting patient results (42 CFR 493.1413(b)(9) and 493.1451(b)(9)).
What are the six elements of competency assessment?
1) Direct observation of routine patient testing, including patient preparation if applicable and specimen handling, processing and testing. 2) Monitoring how results are recorded and reported. 3) Review of intermediate results or worksheets, QC records, PT results and preventive maintenance records. 4) Direct observation of instrument maintenance and function checks. 5) Testing previously analyzed specimens, internal blind samples or external PT samples. 6) Assessment of problem-solving skills.
What is the difference between training and competency assessment?
Training teaches a person to do the task your lab's way before they start. Competency assessment shows they then do it correctly, following your procedures. CMS says neither training records nor performance evaluations can stand in for a CLIA competency assessment. A Joint Commission field director also wrote in MLO (Dec 2025) that The Joint Commission wants initial training and initial competency kept in separate records.
Who can perform competency assessments?
Only people who meet the CLIA qualifications for the role. In moderate complexity testing, that is the technical consultant or someone who meets technical consultant qualifications. In high complexity testing, it is the technical supervisor, who may delegate in writing to a qualified general supervisor. In a PPM-certificate lab, the laboratory director does it. The laboratory director stays responsible for the program.
Can a coworker assess another coworker's competency?
Only if that coworker meets the CLIA qualifications to assess (technical consultant, technical supervisor or general supervisor, depending on test complexity) and the duty has been delegated to them in writing. CMS says anyone who falls short of those qualifications may not assess competency or be assigned to do so. The assessor doesn't need the title on the CMS-209, but they must meet the qualifications.
Does waived testing require competency assessment?
CLIA doesn't require it for staff in a waived-only lab, though CMS recommends it. The Joint Commission goes further for hospitals and critical access hospitals: National Performance Goal 10 (NPG.10.02.01) requires documented training for each waived test, plus competency at orientation and at least annually using at least two of four methods per person per test. For other programs, including the laboratory program, check the waived testing requirements in your current manual.
Does proficiency testing count as competency assessment?
Only partly. PT results can be used for element 5, and PT review is part of element 3. CMS says PT by itself covers only some of the six procedures, so it can't replace a documented competency assessment.
Does the laboratory director need a competency assessment?
If the director performs patient testing, yes. If the director is the only person testing and reporting, CMS says the director must set and document a minimum proficiency level, for example by testing PT samples or having another party review their work. Technical consultants, technical supervisors, general supervisors and clinical consultants also need competency assessments based on their regulatory duties.
Can we assess competency once for all tests on one analyzer?
Be careful. CMS's current brochure says the six procedures apply to every test a person performs, even when several tests run on one platform, and that tests with unique aspects (such as ammonia received on ice) need their own attention. CMS's 2013 guidance, as reported by ADLM, allowed tests on the same test system to be assessed together when none had unique steps. A safe approach is one platform-level assessment that names every test it covers, plus separate assessments for tests with unique handling, manual steps or calculations.
How far back do Joint Commission surveyors review competency records?
The 2025 Laboratory Survey Activity Guide asks for a list of all testing personnel with qualifications, hire dates, and training and competency records for the past 24 months. Surveyors choose files for staff they met during tracers. In small labs of five or six people, they may review almost every file.
Do contracted, per diem and point-of-care staff need competency assessments?
Yes, if they perform testing under your CLIA certificate. The Survey Activity Guide lists the competency process for contracted staff as a topic for the HR session. For non-waived point-of-care testing, nurses and other staff follow the same six-element CLIA rules, and their assessor must meet the CLIA qualifications.
Is there a competency assessment template for CLIA or Joint Commission labs?
Neither CMS nor The Joint Commission requires one specific form. Any format works if it records, for each person and each test or test system, dated evidence for all six elements, the assessor's name and qualification, the result and any remediation. The template on this page gives you a per-test six-element record, a waived testing record and a roster tracker you can copy into your own documents.
Is a signed checklist enough to prove competency?
Not by itself. A checklist is a good way to record evidence, but a box ticked without the underlying proof (the observed run, the reviewed QC log, the blind sample result, the problem-solving case) doesn't show all six elements were assessed. CMS also says training records and performance evaluations can't replace a documented competency assessment.
How long should competency records be kept?
CLIA's retention rule, 42 CFR 493.1105, sets a 2-year minimum for most lab records, including QC and patient test records, PT records, quality system assessment records and test reports. It doesn't list personnel files separately. The Joint Commission's 2025 Laboratory Survey Activity Guide asks for training and competency records covering the past 24 months, so keep at least two years on hand, and longer if your state, your accreditor or your own policy requires it.
Does The Joint Commission require competency only every two years?
Not for non-waived laboratory testing. Some online sources mention a two-year cycle for general hospital staff competencies, but CLIA requires every person doing moderate or high complexity testing to be assessed at least annually after the first year, and The Joint Commission's laboratory standards follow CLIA. Waived testing under NPG 10 is also at least annual.
What is Joint Commission National Performance Goal 10?
It is the waived testing goal. It requires written waived testing policies set by the person named on the CLIA certificate or a qualified designee, documented training for each waived test a person is authorized to do, and competency assessed at orientation and at least annually using more than one method. The Joint Commission's NPG chapter applies to its Hospital and Critical Access Hospital programs as of January 1, 2026.
Is a Joint Commission lab checklist available?
The Joint Commission's public Laboratory Survey Activity Guide lists the documents surveyors ask for, including personnel qualifications, hire dates and 24 months of training and competency records. This page turns the competency part of that list into a file checklist, and our Joint Commission laboratory document list covers the rest of the survey.
Is Sound Lab Consultants affiliated with The Joint Commission?
No. Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or accredited by The Joint Commission or CMS, and nothing on this page is an official interpretation of their requirements.
Sources
- CMS, CLIA: Assessing Personnel Competency brochure (revised May 2025, PDF)
- CMS, State Operations Manual Appendix C, Survey Procedures and Interpretive Guidelines for Laboratories (Rev. 236, Jan 23, 2026, PDF)
- 42 CFR 493.1235 Personnel competency assessment policies
- 42 CFR 493.1413 Technical consultant responsibilities
- 42 CFR 493.1451 Technical supervisor responsibilities
- 42 CFR 493.1463 General supervisor responsibilities
- 42 CFR 493.1407 Laboratory director responsibilities (moderate complexity)
- 42 CFR 493.1445 Laboratory director responsibilities (high complexity)
- 42 CFR 493.1359 PPM laboratory director responsibilities
- 42 CFR 493.15 Laboratories performing waived tests
- The Joint Commission, Laboratory Services Accreditation Program
- The Joint Commission, Laboratory Accreditation Organization Survey Activity Guide 2025 (PDF)
- The Joint Commission, National Performance Goal #10: Waived Testing
- The Joint Commission, National Performance Goals
- The Joint Commission, National Performance Goals Effective January 2026 for the Hospital Program (PDF)
- The Joint Commission, Joint Commission Online, Top 5 most challenging requirements for 2023 (Apr 3, 2024)
- The Joint Commission, HEADS UP: Maintenance and Inspection of Laboratory Equipment (PDF)
- The Joint Commission, HEADS UP: Monitoring and Evaluation During Blood Transfusion (PDF)
- The Joint Commission, HEADS UP: Performing Correlation Testing (PDF)
- 42 CFR 493.1105 Retention requirements
- ADLM Clinical Laboratory News, Competency Assessment: Does the New CLIA Guidance Mean Big Changes? (June 2013)
- MLO, How to prepare for a Joint Commission survey (Dec 22, 2025)
- FDA, CLIA waived analytes database
Related pages
- Joint Commission Laboratory Accreditation Requirements
- Joint Commission Laboratory Survey Preparation
- Joint Commission Laboratory Document List
- Joint Commission Laboratory Tracer Methodology
- Joint Commission Laboratory Proficiency Testing Review
- CLIA competency assessment six elements
- Competency assessment form
- CLIA testing personnel
- COLA vs CAP vs Joint Commission
- Lab survey preparation
Independence note: Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or accredited by The Joint Commission or CMS, and nothing here is an official interpretation of their requirements. Accreditation and survey decisions are made only by The Joint Commission and, where applicable, CMS or the state survey agency.
Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225