Joint Commission Laboratory Proficiency Testing Review
In a Joint Commission laboratory survey, proficiency testing is reviewed in a dedicated session of about 90-180 minutes held immediately after the regulatory review. The 2025 Laboratory Survey Activity Guide says the surveyor verifies enrollment in a CMS-approved PT program for each regulated analyte, reviews the last two years (six events) of results, handling records and signed attestations, and checks documented review and remedial action for every result outside acceptable limits.
Source: Laboratory Accreditation Survey Activity Guide 2025 (The Joint Commission, issued June 23, 2025). Last reviewed: Oct 31, 2026
About the source document
The Laboratory Accreditation Survey Activity Guide 2025 is published by The Joint Commission for its Laboratory Accreditation Program. The edition summarized here carries an issue date of June 23, 2025, with changes effective July 1, 2025. It explains each activity of an on-site laboratory survey: who should attend, how long it usually lasts, what surveyors want to see and what they will ask. It is a survey process guide, not the standards manual itself, so the elements of performance (EPs) for chapters such as Quality System Assessment for Nonwaived Testing (QSA), Document and Process Control (DC), Human Resources (HR) and Leadership (LD) are found in the accreditation manual your organization licenses from The Joint Commission. The only standard numbers the guide itself cites are the infection prevention and control standards IC.04.01.01, IC.06.01.01 and IC.07.01.01. This page paraphrases the guide; always read the current edition on your Joint Commission Connect extranet site before acting on it.
Who attends and what is reviewed
- Lab directors on every CLIA certificate held by the organization, the administrative director or manager and designated staff.
- All PT results for the last two years (previous six events).
- Records of handling, preparation, processing, examination and reporting, and signed attestation statements.
- Documented review of each PT report and of problems or potential problems, with remedial action.
- Performance improvement data and record retention policies.
- From the document list: tests without PT and the alternative performance verifications used for them.
How this relates to CLIA
CLIA PT rules are in 42 CFR Part 493 Subpart H. Surveyors check that PT samples were tested like patient samples and that results were not shared between labs. Our lab proficiency testing requirements page and unsuccessful PT participation page cover the federal side.
Survey preparation steps for PT review
- List every regulated analyte on your menu and match it to a PT enrollment by CLIA number.
- File each event with the shipment receipt, worksheets, instrument printouts, submission and evaluation report.
- Confirm attestations are signed by the director and testing personnel for every event.
- For every unacceptable or ungraded result, write an investigation: clerical, methodological, equipment, technical, PT material; include patient impact and corrective action.
- Show the director or designee review of each evaluation, with dates.
- For tests without PT, document alternative verification at least twice a year and keep results.
- Prepare PI data that shows a measured improvement that was sustained, as the guide asks in orientation.
Common PT findings
- Investigations that say 'clerical error' without a root cause or fix.
- Missing attestation signatures.
- PT handled by only the most experienced tech instead of rotated staff.
- Ungraded results not reviewed.
- Alternative assessment not done for a test added mid-year.
Related services
See proficiency testing and QC consulting and our PT review log.
How Sound Lab Consultants helps
Sound Lab Consultants (SLC) works with clinical laboratories remotely on survey preparation for The Joint Commission, CAP, COLA and state CLIA surveys. Typical work includes a gap review against the Survey Activity Guide document list, mock tracers through each specialty, proficiency testing and QC record review, IQCP review, competency assessment programs, emergency management and infection control document reviews, and help writing corrective action after a survey. Start with our CLIA consultant and clinical laboratory consulting pages, or see the CLIA mock inspection service.
Independence note
Sound Lab Consultants is an independent consulting firm. It is not affiliated with, endorsed by or accredited by The Joint Commission, and nothing on this page is an official interpretation of Joint Commission standards. Survey decisions are made only by The Joint Commission and, where applicable, CMS.
Frequently asked questions
How many PT events do Joint Commission surveyors review?
The last two years, which the guide describes as the previous six testing events. Source: The Joint Commission, Laboratory Accreditation Organization Survey Activity Guide 2025 (PDF).
When is PT reviewed?
Immediately after the regulatory review on day one, for about 90-180 minutes. Source: The Joint Commission, Laboratory Accreditation Organization Survey Activity Guide 2025 (PDF).
What about tests with no PT program?
The document list asks for a list of those tests and the results of alternative performance verifications. Source: The Joint Commission, Laboratory Accreditation Organization Survey Activity Guide 2025 (PDF), 42 CFR Part 493 Subpart H - Proficiency Testing (eCFR).
Is PT data needed for an initial survey?
Yes. The guide's four-month exception for initial surveys does not apply to proficiency data; it asks for 24 months for initial surveys and resurveys. Source: The Joint Commission, Laboratory Accreditation Organization Survey Activity Guide 2025 (PDF).
Sources
- The Joint Commission, Laboratory Accreditation Organization Survey Activity Guide 2025 (PDF)
- 42 CFR Part 493 Subpart H - Proficiency Testing (eCFR)
- 42 CFR Part 493 (eCFR)
Related pages
- Joint Commission Laboratory Accreditation Requirements
- Joint Commission Laboratory Survey Preparation
- Joint Commission Laboratory Document List
- Joint Commission Laboratory Tracer Methodology
- Joint Commission Laboratory Competency Assessment
- Joint Commission Laboratory Infection Prevention and Control Requirements
- Joint Commission Laboratory Emergency Management and Environment of Care
- Joint Commission Laboratory Regulatory Review and IQCP
- CLIA consultant
- clinical laboratory consulting
- CLIA mock inspection
- how to prepare for a lab inspection
- COLA vs CAP vs Joint Commission
- CLIA, CAP, COLA and TJC regulations
Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225