How to Improve Hospital Lab Profitability

Hospital labs usually improve profitability by auditing send-outs, calculating a true cost per test before bringing tests in-house, cutting unnecessary utilization and repeats, and fixing billing denials. Any test moved in-house must be within the lab's CLIA certificate and verified before patient use (42 CFR 493.1253), and tests that stay out must go only to CLIA-certified labs (493.1242(c)).

Last reviewed: Oct 31, 2026

Book a free consultation

Balance scale weighing specimen tubes against a laboratory analyzer, illustrating send-out versus in-house testing

Step 1: Audit your send-outs

  • Pull 12 months of send-out volume by test, ordering department and reference lab.
  • For each test, record the reference lab charge, courier cost, turnaround time and how often results drive same-stay decisions.
  • Flag tests where long turnaround delays discharge or treatment; these have value beyond the invoice.
  • Check that each reference lab is CLIA-certified for the tests sent (493.1242(c)).

Step 2: Calculate true cost per test before bringing it in

Cost componentInclude
Reagents and consumablesPer reportable result, including repeats, dilutions and expired reagent waste
Quality control and calibrationControl material, calibrators, runs per day required by your QC plan (493.1256)
Proficiency testingEnrollment for regulated analytes, or twice-yearly accuracy checks for others (493.1236)
LaborBench time, technical review, supervision, competency assessment
InstrumentLease or depreciation, service contract, downtime backup
VerificationAccuracy, precision, reportable range and reference interval studies (493.1253)
ITLIS build, interface and report formatting (493.1291)

Compare that cost with the reference lab charge plus courier, and with expected reimbursement. Medicare outpatient payment for many tests is set on the CMS Clinical Laboratory Fee Schedule; inpatient tests are usually bundled into the hospital stay payment.

Step 3: Reduce waste you already pay for

  • Duplicate orders within the same stay; add order-entry rules where medical staff agree.
  • Specimen rejection and redraws: track rejection reasons and fix the top causes at collection.
  • QC overuse or underuse: right-size QC frequency using your documented QC plan.
  • Reagent expiration: match kit sizes and standing orders to real volume.
  • Billing denials: missing diagnosis codes and medical necessity documentation. See lab billing denial management.
Rack of blood collection tubes with colored caps

Step 4: Keep compliance intact while you change

  • Confirm the new test's complexity in the FDA CLIA database and that your certificate covers the specialty; update the CMS-116 if not.
  • Complete and sign verification studies before the go-live date.
  • Add the test to PT enrollment or the twice-yearly accuracy verification schedule.
  • Update the procedure manual, LIS reference ranges and client instructions.
  • Train and document competency for every person who will run it.

Common survey problems after a test is brought in-house

  • Patient results reported before the director signed the verification.
  • No PT or alternative assessment for the new analyte.
  • Reference intervals copied from the package insert without verification.
  • LIS report shows the old reference lab's name or ranges.

Records to keep

  • Send-out audit and the cost per test worksheet behind each decision.
  • Verification studies and director approval.
  • PT enrollment or accuracy verification records.
  • Reference lab CLIA certificates.
  • Utilization and denial reports reviewed by lab leadership.

How SLC helps

We run send-out audits, build cost per test worksheets, verify new tests and update procedures and PT plans so in-house moves stay compliant. See hospital lab consulting, hospital laboratory management services and lab revenue cycle management.

Frequently asked questions

Can a hospital lab send tests to any reference lab?

No. 42 CFR 493.1242(c) allows referral only to a CLIA-certified lab or one meeting equivalent requirements as determined by CMS. Source: eCFR 42 CFR § 493.1242.

What must be done before bringing a send-out test in-house?

For an unmodified FDA-cleared or approved test, verify accuracy, precision, reportable range and reference intervals before reporting patient results (42 CFR 493.1253); modified or lab-developed tests need full validation. Source: eCFR 42 CFR § 493.1253.

Does a new in-house test need proficiency testing?

Regulated analytes need PT through a CMS-approved program. For tests without PT, the lab must verify accuracy at least twice a year (42 CFR 493.1236(c)). Source: eCFR 42 CFR § 493.1236.

Where can I check Medicare outpatient lab payment amounts?

On the CMS Clinical Laboratory Fee Schedule page, which posts the current files. Source: CMS - Clinical Laboratory Fee Schedule.

How do I check a test's CLIA complexity?

Search the FDA CLIA test categorization database by test system or analyte. Source: FDA - CLIA Test Categorization Database.

Sources

Related pages

Book a free consultation

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.