COVID-19 Antigen and PCR Testing CLIA Requirements
The CLIA requirements for a COVID-19 test depend on how the FDA categorized that specific test system. Waived antigen tests need at least a CLIA Certificate of Waiver and must follow the manufacturer's instructions exactly (42 CFR 493.15). Moderate and high complexity PCR or antigen tests need a Certificate of Compliance or Accreditation, a qualified director, performance verification before patient use (493.1253), QC and accuracy checks, and documented personnel competency.
Last reviewed: Oct 31, 2026

Find your test's complexity first
- Look up the exact test system in the FDA CLIA database; antigen and molecular tests from different makers can fall in different categories.
- Check whether the test is authorized under an Emergency Use Authorization or cleared or approved; EUA status and conditions are posted on FDA's In Vitro Diagnostics EUAs page.
- Match the certificate: Certificate of Waiver for waived only; Certificate of Compliance or Accreditation for moderate or high complexity. Update the CMS-116 before adding a non-waived test.
Checklist: waived antigen testing
- Certificate of Waiver covering the site.
- Current package insert at the testing area; follow it exactly, including external QC frequency and storage temperature (493.15).
- Kit lot and expiration log, storage temperature log.
- Training records for each person who tests.
- Result reporting process, including any state public health reporting that applies.
Checklist: moderate or high complexity PCR or antigen
- Director and technical consultant or supervisor qualified for the complexity (Subpart M).
- Verification of accuracy, precision, reportable range and reference interval before patient testing (493.1253).
- QC per 493.1256 or an approved IQCP; document every run.
- Molecular contamination control: unidirectional workflow, separate pre- and post-amplification areas, surface wipe tests.
- PT through a CMS-approved program if offered, or twice-yearly accuracy verification (493.1236).
- Competency for each testing person at six months and annually in the first year, then annually.

Common survey problems in respiratory testing
- Testing a moderate complexity system under a Certificate of Waiver.
- Waived kits stored outside the package insert temperature range with no log.
- Package insert version changed but the procedure was not updated.
- No accuracy verification for an analyte without approved PT.
- Results transcribed by hand into the EHR without a verification check (493.1291).
Records to keep
- CLIA certificate and CMS-116 updates.
- Verification studies with director sign-off.
- QC, temperature and kit lot logs: at least 2 years (493.1105).
- PT or accuracy verification records: at least 2 years.
- Test reports: at least 2 years.
- Personnel training and competency.
How SLC helps
We help clinics, urgent care sites and labs confirm the right certificate, write procedures from the package insert, run verification studies for non-waived systems and set up QC and competency records. See IQCP for molecular testing and CLIA consultant.
Frequently asked questions
Do I need a CLIA certificate to run COVID-19 rapid antigen tests?
Yes. Any site testing patient specimens for diagnosis needs a CLIA certificate; a waived test needs at least a Certificate of Waiver. Source: CMS - Clinical Laboratory Improvement Amendments (CLIA), eCFR 42 CFR § 493.15.
Is COVID-19 PCR testing waived?
It depends on the specific test system. Some molecular tests are categorized as waived and many are moderate or high complexity; check the FDA CLIA database. Source: FDA - CLIA Test Categorization Database.
What must be verified before starting a non-waived COVID-19 test?
Accuracy, precision, reportable range and reference interval for an unmodified FDA-cleared, approved or authorized test (42 CFR 493.1253). Source: eCFR 42 CFR § 493.1253.
What if no proficiency testing is available for my test?
The lab must verify the accuracy of tests not covered by approved PT at least twice a year (42 CFR 493.1236(c)). Source: eCFR 42 CFR § 493.1236.
Where can I check a test's EUA status?
FDA lists in vitro diagnostic EUAs, including SARS-CoV-2 tests, on its In Vitro Diagnostics EUAs page. Source: FDA - In Vitro Diagnostics EUAs.
Sources
- eCFR 42 CFR § 493.15
- eCFR 42 CFR § 493.1253
- eCFR 42 CFR § 493.1256
- eCFR 42 CFR § 493.1236
- eCFR 42 CFR § 493.1105
- eCFR 42 CFR § 493.1291
- FDA - CLIA Test Categorization Database
- FDA - In Vitro Diagnostics EUAs
- CMS-116 CLIA Application for Certification (PDF)
- CMS - Clinical Laboratory Improvement Amendments (CLIA)
Related pages
- Anatomic Pathology Lab Consulting
- Histology Lab Setup and Compliance
- Cytology Lab CLIA Requirements
- How to Improve Hospital Lab Profitability
- Clinical laboratory consulting
- CLIA consultant
- New lab setup
- Clinical lab setup checklist
- Lab management consulting
- Laboratory director services
- Hospital lab consulting
- Dermatology technical lab consultant
- Proficiency testing and quality control consulting
- Failed COLA, CLIA or CAP survey
