CLIA Quality Assessment Plan

A CLIA quality assessment plan is the written program a non-waived lab uses to monitor, assess and correct problems across its whole testing process. 42 CFR 493.1200 requires the quality system to include an assessment component, and 493.1239, 493.1249, 493.1289 and 493.1299 require ongoing quality assessment of general, preanalytic, analytic and postanalytic systems. The plan should name what is monitored, how often, who reviews it, how problems are corrected and how results are shared with staff.

Last reviewed: Oct 31, 2026

Book a free consultation

What a QA plan should cover

SystemExample monitorsCLIA section
General laboratory systemsComplaints, communication breakdowns, competency completion, personnel file currency, PT review timeliness493.1239
PreanalyticRequisition completeness, specimen rejection and labeling errors, transport conditions493.1249
AnalyticQC failures and corrective actions, calibration verification, method comparisons, PT results, maintenance493.1289
PostanalyticReport errors and corrected reports, critical value notification, turnaround time493.1299
Clipboard checklist beside a printed quality plan document
Clipboard checklist beside a printed quality plan document

QA plan checklist

  • Scope: every test site, specialty and test system on the CLIA certificate.
  • Named monitors with a definition, data source, threshold and review frequency.
  • Responsible reviewer for each monitor and director sign-off.
  • Written steps for investigating problems and documenting corrective action (493.1282 for analytic failures).
  • Twice-yearly comparison of results when the same test is run on different methods, instruments or sites (493.1281).
  • Review of PT and alternative assessment results with follow-up of unacceptable results.
  • Staff communication: how QA findings are discussed and documented.
  • Annual review of the plan itself, with changes approved by the director.

Common survey problems

  • A QA policy exists but no monitoring data or review records.
  • Monitors that only cover QC, leaving preanalytic and postanalytic errors untracked.
  • Problems identified but no corrective action or follow-up showing the fix worked.
  • No twice-yearly comparison between instruments running the same test.
  • QA reviews not shared with staff or not signed by the responsible person.
  • Corrected reports issued without tracking why the error happened.

Records to keep

  • The approved QA plan and its revision history.
  • Monitor data, review notes and director sign-offs.
  • Corrective action and follow-up records.
  • Method comparison records.
  • Staff meeting minutes or acknowledgements covering QA findings.
  • Retention for at least the periods in 42 CFR 493.1105.
Laboratory analyzer next to a clipboard review log with most items checked
Laboratory analyzer next to a clipboard review log with most items checked

How Sound Lab Consultants helps

We work with labs to write QA plans sized to their test menu, choose monitors that surveyors look for, set up review logs and run periodic QA reviews as part of technical consultant oversight. Related: laboratory KPIs and quality indicators, laboratory corrective action (CAPA), QC program design.

Frequently asked questions

Is a quality assessment plan required under CLIA?

Non-waived labs must have a quality system that includes ongoing quality assessment of general, preanalytic, analytic and postanalytic systems. Source: 42 CFR 493.1200 Introduction to the quality system (eCFR), 42 CFR 493.1239 General laboratory systems quality assessment (eCFR), 42 CFR 493.1289 Analytic systems quality assessment (eCFR), 42 CFR 493.1299 Postanalytic systems quality assessment (eCFR).

How often must labs compare results across instruments?

At least twice a year when the lab uses more than one method, instrument or site for the same test. Source: 42 CFR 493.1281 Comparison of test results (eCFR).

Does QA have to be shared with staff?

CLIA quality assessment standards require that QA reviews include staff and that problems and corrective actions are documented. Source: 42 CFR 493.1239 General laboratory systems quality assessment (eCFR), CMS State Operations Manual Appendix C (PDF).

Do waived labs need a QA plan?

The Subpart K quality system requirements apply to non-waived testing; waived labs must follow manufacturer instructions. Source: 42 CFR 493.1200 Introduction to the quality system (eCFR), 42 CFR Part 493 (eCFR).

Sources

Related pages

Book a free consultation

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.