Sound Lab Consultants · Clinical laboratory consulting

MolDX Technical Assessment Dossier Checklist

Last reviewed: November 8, 2026

Quick answer

A MolDX dossier should connect the registered assay and intended use to the required forms, validation report, supporting data and clinical evidence. Use the live MolDX submission checklist and the forms for your assay category. A generic marketing deck is not an evidence package.

Start with the current official checklist

The MolDX Technical Assessment Forms page lists GEN-CQM-003, the Technical Assessment Submission Checklist, and assay-specific forms. Examples include SOM-PF-004 for solid-tumor testing and PGX-PF-007 for pharmacogenomics. Download the current files for the actual submission; this page does not freeze a form revision or reproduce the full official checklist.

The MolDX Technical Assessment FAQs recommends a clear intended-use description, details of orthogonal methods, calculation formulas, sample-level data and the validation report. Someone familiar with the validation should complete the documentation.

Suggested dossier index

SectionSuggested contentsConsistency check
Assay identityTest name, DEX identifier, internal ID, version and performing organization.Matches the registered service.
Intended usePopulation, specimen, clinical question and role in care.Matches the claimed coverage indication.
Analytical evidenceValidation report, study protocols, acceptance criteria, calculations and sample-level data.Supports each reported specimen and result class.
Clinical evidenceClinical-validity and utility literature mapped to the use.Explains applicability and limitations.
ReportingRepresentative report and interpretation logic.Delivers the claimed clinical information.
Submission controlCurrent forms, evidence index and response history.Every requested item has a retrievable location.

This index is an SLC organizational aid. The official checklist and reviewer requests determine the required submission materials.

Make every claim traceable

For each performance statement, point to the validation protocol, source data and approved conclusion. If a claimed specimen or variant type is not supported, mark the gap and resolve it rather than broadening the summary language. Use the same intended-use language across the DEX record, forms, report and clinical-evidence narrative.

  1. Create an evidence table with requirement, source file, section and conclusion.
  2. Separate raw observations from calculated results and explain formulas.
  3. Document orthogonal comparison methods and discordance investigations.
  4. List limitations and unsupported uses explicitly.
  5. Review every figure, table and attachment against the final version submitted.

One platform can support several registered tests

The MolDX Technical Assessment FAQs allows validation of a test as part of a larger panel or platform validation, but asks that each single gene or gene group offered and billed as a test have its own DEX registration. The executive summary should map the identifiers to the validation documents.

Do not assume platform-level validation automatically establishes clinical utility for each smaller test. Link the specific reported service to both its analytical support and its clinical purpose. For assay-specific preparation, see NGS oncology assessments and PGx testing.

Frequently asked questions

Which MolDX checklist should we use?

Download the current Technical Assessment Submission Checklist, GEN-CQM-003, from the official MolDX forms page and add the applicable assay-specific forms.

Are sample-level data useful?

Yes. MolDX assessment FAQs specifically recommend sample-level data, formulas, orthogonal-method details and the validation report.

Can one validation support subpanels?

MolDX accepts validation performed within a larger panel or platform, but each separately offered and billed test must be registered and mapped to its supporting evidence.

Does this checklist guarantee a complete submission?

No. It is an organizational aid. Use the current official checklist, assay-specific forms and any reviewer requests as the controlling requirements.

Official sources

Sound Lab Consultants provides independent consulting. SLC is not affiliated with CMS, Palmetto GBA, DEX or any payer. This educational reference is not legal advice, a coverage determination or a guarantee of approval or payment. Official policies and effective dates control. Sound Lab Consultants: 25 Arizona Pl, Chandler, AZ 85225.

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide