Bio-Rad Unity QC Consulting for CLIA Labs

Bio-Rad Unity software gives a lab charts, rules and peer statistics for its control data. It does not write the lab's QC plan, decide its acceptance criteria, or document why a run was released. Under CLIA, those duties stay with the lab director and technical staff. Sound Lab Consultants helps labs that use Bio-Rad controls and Unity tools turn that data into a QC program that holds up during a CLIA, CAP, COLA or Joint Commission survey.

Sound Lab Consultants (SLC) is an independent clinical laboratory compliance consulting firm. We do not sell, install or support Bio-Rad software. We review how your lab uses it, then help you design QC rules, written procedures, review steps, corrective action records and IQCP documents that line up with 42 CFR Part 493 and your accreditor's checklist.

Gloved hands attaching a pipette to a pipette aid in a clinical laboratory
Photo: Diane A. Reid, public domain, via Wikimedia Commons

What the Unity family does, in plain terms

Bio-Rad groups several QC data products under the Unity name, and lab staff often use the names loosely. Based on Bio-Rad's public documentation:

  • Unity Real Time is QC data management software. The Unity Real Time 2 User Guide lists Levey-Jennings and other charts, bench and supervisor review, Westgard (SPC) rule settings, lab, lot, test and panel setup, multi-test data entry and user security.
  • Unity Real Time online / UnityWeb are browser versions reached through QCNet. The online help describes bench review and supervisor review, automatic action logs, an audit trail report and data export.
  • Unity Interlaboratory Program compares a lab's control results with other labs using the same control lot. Bio-Rad's program brochure says monthly peer reports are posted on QCNet and that on-demand InstantQC reports are available for troubleshooting.
  • Unity Next Peer QC is described by Bio-Rad as its newer peer comparison tool, with instant peer reports, no submission deadline and digital sign-off.
  • Westgard Advisor is an optional feature that, per the online help, suggests SPC rules and the number of controls per run from the lab's data, a selected allowable total error (TEa) and a consensus group.

All of these tools sit on top of control material. Most labs that use Unity run Bio-Rad third-party controls such as Lyphochek (lyophilized), Liquichek (liquid, ready to use) or InteliQ (barcoded load-and-go tubes), which Bio-Rad lists on its quality controls page.

Where software stops and CLIA starts

CLIA does not require any QC software. It requires outcomes. 42 CFR 493.1256 says each test system must have control procedures that monitor the accuracy and precision of the complete analytic process, and that the lab must set the number, type and frequency of control testing. Paragraph (d)(10) says the lab must establish or verify acceptability criteria for every control material, with mean and standard deviation defined and available for each lot. Paragraph (f) says controls must meet those criteria before patient results are reported, and (g) says all control procedures must be documented.

When a control fails, 42 CFR 493.1282 requires documented corrective action, including an evaluation of every patient result from the unacceptable run back to the last acceptable run. 42 CFR 493.1235 requires written policies for assessing staff competency, which in practice includes whether each person can interpret QC and act on a rejection correctly.

A Unity rule flag is evidence that a rule was broken. It is not evidence that the lab looked at affected patients, found a cause or confirmed the fix. That gap is where most QC citations come from, and it is the gap SLC works on.

Common problems we find in Unity-based QC programs

Labs that use Unity well still run into the same handful of issues. None of them are software defects; they are setup and procedure choices:

  • Rules turned on in the software that do not match the rules written in the QC procedure, or a procedure that says "Westgard rules" without naming which ones.
  • Means and SDs copied from the control insert range and never replaced with the lab's own data, so the limits are too wide to catch real shifts.
  • Warning rules treated as rejection rules, which trains staff to repeat controls until they pass.
  • Action log entries such as "repeated, OK" with no cause, no patient look-back and no reviewer.
  • Peer reports printed every month but never signed, dated or acted on.
  • New control lots started without a documented crossover period, or with targets set from too few points.
  • Supervisor review done in the software but not described in the written procedure, so a surveyor cannot tell who is responsible.
  • IQCP documents that mention Unity but do not show how QC data feeds the risk assessment or the quality assessment review.

What SLC does for labs using Bio-Rad controls and Unity

Our work is consulting and documentation. You keep running the software; we help you make the program behind it defensible.

  • QC program design and review. We map each test system to its control materials, levels, frequency and acceptance criteria, and check them against 42 CFR 493.1256 and the manufacturer's instructions.
  • Westgard rule selection guidance. We review which SPC rules are active in Unity Real Time for each analyte, compare them with your quality goals, and help you write the rule choice and its reason into the QC procedure.
  • Peer report review process. We help you decide who reviews Unity Interlab or Unity Next reports, how often, what SDI or bias triggers follow-up, and how review is documented.
  • Lot change and crossover procedures. We write a repeatable process for starting new Lyphochek, Liquichek or InteliQ lots and setting lab-specific targets.
  • Corrective action and CAPA. We build QC failure investigation templates and train staff to complete them, including the patient look-back required by 493.1282.
  • IQCP. Where IQCP is allowed, we help you use your historical QC and peer data as part of the risk assessment and quality assessment.
  • Mock surveys and survey preparation. We review QC records the way a CLIA, CAP, COLA or Joint Commission surveyor would and give you a written list of fixes.
  • Lab director services. For labs that need one, SLC offers qualified laboratory director and technical consultant support.

How an engagement usually runs

Most Unity-related projects follow the same path, scaled to the size of the lab:

  • Intake. We start with a free consultation to learn your test menu, instruments, control products and accreditor.
  • Record review. You share a sample of QC procedures, Unity rule settings or screenshots, Levey-Jennings charts, action logs, peer reports and recent corrective actions. We do not need your Unity login; exported reports or screenshots are enough.
  • Gap list. We give you a written list of gaps tied to the CLIA section or accreditor requirement each one relates to.
  • Fixes. We draft or revise procedures, forms and review checklists, and help your team apply them.
  • Training and follow-up. We walk staff through the revised process and can check a later month of records to confirm it is being followed.

Work can be remote, on site, or a mix, depending on what the lab needs.

The series: Bio-Rad Unity QC topics in depth

This page is the hub for a set of guides on running a Bio-Rad based QC program under CLIA. Each guide covers one part of the program in more detail:

For the regulatory basics behind all of them, see our pages on CLIA quality control requirements and Westgard rules under CLIA.

What surveyors usually ask about QC

Whatever software a lab uses, survey questions about QC tend to follow the same thread. A surveyor picks a test, a date and a run, and asks to see:

  • The written QC procedure for that test, approved by the director.
  • The control lots in use, with their targets and how those targets were set.
  • The QC results for the run, and evidence they were reviewed before patients were reported.
  • Any rule violations that month, and the corrective action for each, including patient review.
  • Who reviewed QC at the supervisor or director level, and when.
  • Peer or proficiency testing results for the same analyte and how problems were followed up.
  • Competency records showing the testing person was assessed on QC.

If each of those pieces can be found quickly and tells the same story, QC questions are usually short. If the software says one thing and the procedure says another, they are not. Our CLIA mock inspection service tests that thread before the real survey.

Frequently asked questions

Is Sound Lab Consultants part of Bio-Rad?

No. SLC is an independent consulting firm. We are not affiliated with, endorsed by or a reseller of Bio-Rad. For software licensing, installation, login or technical support, contact Bio-Rad through QCNet.

Do I need Unity software to meet CLIA QC rules?

No. CLIA requires control procedures, acceptability criteria, review and documentation under 42 CFR 493.1256 and corrective action under 42 CFR 493.1282. It does not name a product. Unity is one way to manage and document QC data.

Can SLC help me pick Westgard rules in Unity Real Time?

Yes. We review the SPC rules active for each test, compare them with your quality goals and the lab's own performance, and help you document the selection and its reasons in your QC procedure. The lab director makes the final decision.

Does SLC need access to our Unity account?

Usually not. Exported reports, Levey-Jennings charts, rule setting screenshots, action logs and peer reports are normally enough for a review. Keep your login credentials within your lab.

Do Unity peer reports replace proficiency testing?

No. Bio-Rad itself describes the Unity Interlaboratory Program as a complement to PT. CLIA proficiency testing enrollment and evaluation requirements still apply, including review under 42 CFR 493.1236.

What does a Unity QC consulting project cost?

It depends on the number of test systems, sites and records involved. We scope the work after a free consultation and give you a written estimate before anything starts.

Which accreditors does SLC prepare labs for?

SLC supports CLIA, CAP, COLA and Joint Commission survey preparation, including mock surveys focused on QC records.

Sources: 42 CFR 493.1256 Control procedures; 42 CFR 493.1282 Corrective actions; 42 CFR 493.1235 Competency policies; 42 CFR 493.1236 PT evaluation; Bio-Rad Unity Real Time 2 User Guide (PDF); QCNet help: Bench and Supervisor Review; QCNet help: Automatic Action Logs; QCNet help: Westgard Advisor online; Bio-Rad Unity Interlaboratory Program (PDF); Bio-Rad Unity Next Peer QC; Bio-Rad quality control products.

Related SLC pages: CLIA quality control requirements, Westgard rules and CLIA QC, QC corrective action documentation, IQCP consulting, CLIA mock inspection, CLIA laboratory director services.

Want an independent review of your Bio-Rad QC program before your next survey?

Book a free consultation

Bio-Rad, Unity, Unity Real Time, UnityWeb, Unity Next, QCNet, InstantQC, Westgard Advisor, EQAS, Lyphochek, Liquichek and InteliQ are trademarks of Bio-Rad Laboratories, Inc. Sound Lab Consultants is an independent consulting firm and is not affiliated with or endorsed by Bio-Rad. Product details on this page come from Bio-Rad's public pages and user documentation, linked below; confirm current features with Bio-Rad. This page is general information, not legal advice.

Sound Lab Consultants · 25 Arizona Pl, Chandler, AZ 85225

Sound Lab Consultants Logo

Clinical Lab Growth & Compliance Experts helping labs launch, scale, and pass inspections with confidence.

📧 sales@soundlabconsult.com

📍 Headquarters: 25 Arizona Pl, Chandler, AZ 85225
Serving laboratories nationwide in all 50 states

Services

  • CLIA, COLA & CAP Consulting
  • Lab Startup & Buildout
  • Inspection Preparation
  • Lab Billing & Revenue Cycle
  • Staff Training & Compliance

Get Started

Ready to build or scale your lab?

Schedule a Consultation

Trusted by labs nationwide

© 2026 Sound Lab Consultants. All rights reserved.